Related Experiment Video
Updated: Oct 9, 2025

Murine Echocardiography of Left Atrium, Aorta, and Pulmonary Artery
Published on: February 20, 2017
Artificial Intelligence-Based Echocardiographic Left Atrial Volume Measurement with Pulmonary Vein Comparison
Mengyun Zhu1, Ximin Fan1, Weijing Liu1
1Department of Cardiology, Shanghai Tenth People's Hospital, Tongji University School of Medicine, Shanghai 200072, China.
Abstract:
This paper combines echocardiographic signal processing and artificial intelligence technology to propose a deep neural network model adapted to echocardiographic signals to achieve left atrial volume measurement and automatic assessment of pulmonary veins efficiently and quickly. Based on the echocardiographic signal generation mechanism and detection method, an experimental scheme for the echocardiographic signal acquisition was designed. The echocardiographic signal data of healthy subjects were measured in four different experimental states, and a database of left atrial volume measurements and pulmonary veins was constructed. Combining the correspondence between ECG signals and echocardiographic signals in the time domain, a series of preprocessing such as denoising, feature point localization, and segmentation of the cardiac cycle was realized by wavelet transform and threshold method to complete the data collection. This paper proposes a comparative model based on artificial intelligence, adapts to the characteristics of one-dimensional time-series echocardiographic signals, automatically extracts the deep features of echocardiographic signals, effectively reduces the subjective influence of manual feature selection, and realizes the automatic classification and evaluation of human left atrial volume measurement and pulmonary veins under different states. The experimental results show that the proposed BP neural network model has good adaptability and classification performance in the tasks of LV volume measurement and pulmonary vein automatic classification evaluation and achieves an average test accuracy of over 96.58%. The average root-mean-square error percentage of signal compression is only 0.65% by extracting the coding features of the original echocardiographic signal through the convolutional autoencoder, which completes the signal compression with low loss. Comparing the training time and classification accuracy of the LSTM network with the original signal and encoded features, the experimental results show that the AI model can greatly reduce the model training time cost and achieve an average accuracy of 97.97% in the test set and increase the real-time performance of the left atrial volume measurement and pulmonary vein evaluation as well as the security of the data transmission process, which is very important for the comparison of left atrial volume measurement and pulmonary vein. It is of great practical importance to compare left atrial volume measurements with pulmonary veins.
More Related Videos
04:29Author Spotlight: Advancements in Intracardiac Echocardiography for Atrial Anatomy Assessment
Published on: June 30, 2023
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...