Related Experiment Video
Updated: Oct 9, 2025

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Diagnostic values of different ECG durations in paroxysmal AF diagnosis
1Department of Clinical Electrophysiology, Harrison International Peace Hospital, Hengshui, China.
Objective:
To evaluate the application value of different-duration electrocardiograms (ECGs) in paroxysmal atrial fibrillation (AF) diagnosis.
Methods:
A total of 220 patients with paroxysmal atrial fibrillation diagnosed by 24-h dynamic electrocardiogram in our hospital from January 2019 to December 2020 were selected as the study subjects. The patients were monitored for 10 s, 5 min, and 24 hr, respectively. The results of the three different-duration ECGs were compared and analyzed in order to evaluate their paroxysmal AF diagnosis value.
Results:
Paroxysmal AF was detected in 18 patients (8.2%) with the 10-s ECG; in 89 patients (40.5%) with the 5-min ECG; and in 199 patients (90.5%) with the 24-h dynamic ECG.
Conclusion:
In patients with paroxysmal AF, ECGs with longer detection times had higher detection rates.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Dysrhythmias III: Characteristics of Dysrhythmias
Dysrhythmias IV: Characteristics of Bradyarrhythmias