Differential Organic Contaminant Ionization Source Detection and Identification in Environmental Waters by
Brian Ng1,2, Natalia Quinete1,2, Piero Gardinali1,2
1Institute of Environment, Florida International University, Modesto A. Maidique Campus, Miami, Florida, USA.
Abstract:
The development of nontargeted analysis (NTA) methods to assess environmental contaminants of emerging concern, which are not commonly monitored, is paramount, especially when no previous knowledge on the identity of the pollution source is available. We compared complementary ionization techniques, namely electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), in the detection and identification of organic contaminants in tap and surface waters from South Florida. Furthermore, the performance of a simple rationalized NTA method was assessed by analyzing 10 complex mixtures as part of the US Environmental Protection Agency's Non-targeted Analysis Collaborative Trial interlaboratory study, where limitations of the NTA approach have been identified (e.g., number of employed databases, false positives). Different water bodies displayed unique chemical features that can be used as chemical fingerprints for source tracking and discrimination. The APCI technique detected at least threefold as many chemical features as ESI in environmental water samples, corroborating the fact that APCI is more energetic and can ionize certain classes of compounds that are traditionally difficult to ionize by liquid chromatography-mass spectrometry. Kendrick mass defect plots and Van Krevelen diagrams were applied to elucidate unique patterns and theoretical chemical space regions of anthropogenic organic compounds belonging to homologous series or similar classes covered by ESI and APCI. Overall, APCI and ESI were established as complementary, expanding the detected NTA chemical space which would otherwise be underestimated by a single ionization source operated in a single polarity setting. Environ Toxicol Chem 2022;41:1154-1164. © 2021 SETAC.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
07:13Early Detection of Cyanobacterial Blooms and Associated Cyanotoxins using Fast Detection Strategy
Published on: February 25, 2021
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Ion-Exchange Chromatography
Gas Chromatography: Types of Detectors-II
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Chemical Ionization (CI) Mass Spectrometry