Quantification of physical stress experienced by obstetrics and gynecology sonographers: A comparative study of two
Yong-Ku Kong1, Min-Uk Cho1, Chae-Won Park1
1Department of Industrial Engineering, Sungkyunkwan University, Suwon, South Korea.
Abstract:
This study aims to quantify the stresses of sonographers using two different ultrasound devices, one of conventional and one of ergonomic design. A total of 20 obstetricians and gynecologists participated in this study, and two types of tasks (scanning and positioning) were evaluated while using the two different devices. To quantify workload, four dependent variables (muscle activity, estimated grip force, subjective comfort rating, and task time) were measured. The muscular activity required while using the conventional device was 14.4% MVC (Maximum voluntary contraction) for the scanning task, which was significantly higher than that of the ergonomic device. The subjective comfort rating for the conventional design was lower than that of the ergonomic design. For the positioning task, the ergonomic device (33.2% MVC) resulted in significantly higher muscle activity in the extensor digitorum (ED) and flexor digitorum superficialis (FDS) than the conventional design (22.2% MVC), whereas the deltoid muscle showed significantly lower activity than in users of conventional design (4.5% MVC). Ergonomically-designed ultrasound devices improve ease of moving and the probe's supporters, reduce physical load and increase ease of use for sonographers. Our results may be used as guidelines for usability testing of ultrasound devices.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies II: Ultrasonography
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...