Related Experiment Video
Updated: Oct 9, 2025

Author Spotlight: Assessing the Feasibility of Using Amplitude-Integrated EEG During Neonatal Transport
Published on: June 21, 2024
Comparison of electronic versus manual abstraction for 2 standardized perinatal care measures
Stephen Schmaltz1, Jocelyn Vaughn2, Tricia Elliott3
1Department of Research, The Joint Commission, Division of Healthcare Quality Evaluation, Oakbrook Terrace, Illinois, USA.
Objective:
Given that electronic clinical quality measures (eCQMs) are playing a central role in quality improvement applications nationwide, a stronger evidence base demonstrating their reliability is critically needed. To assess the reliability of electronic health record-extracted data elements and measure results for the Elective Delivery and Exclusive Breast Milk Feeding measures (vs manual abstraction) among a national sample of US acute care hospitals, as well as common sources of discrepancies and change over time.
Materials And Methods:
eCQM and chart-abstracted data for the same patients were matched and compared at the data element and measure level for hospitals submitting both sources of data to The Joint Commission between 2017 and 2019. Sensitivity, specificity, and kappa statistics were used to assess reliability.
Results:
Although eCQM denominator reliability had moderate to substantial agreement for both measures and both improved over time (Elective Delivery: kappa = 0.59 [95% confidence interval (CI), 0.58-0.61] in 2017 and 0.84 [95% CI, 083-0.85] in 2019; Exclusive Breast Milk Feeding: kappa = 0.58 [95% CI, 0.54-0.62] in 2017 and 0.70 [95% CI, 0.67-0.73] in 2019), the numerator status reliability was poor for Elective Delivery (kappa = 0.08 [95% CI, 0.03-0.12] in 2017 and 0.10 [95% CI, 0.05-0.15] in 2019) but near perfect for Exclusive Breast Milk Feeding (kappa = 0.85 [0.83, 0.87] in 2017 and 0.84 [0.83, 0.85] in 2019). The failure of the eCQM to accurately capture estimated gestational age, conditions possibly justifying elective delivery, active labor, and medical induction were the main reasons for the discrepancies.
Conclusions:
Although eCQM denominator reliability for the Elective Delivery and Exclusive Breast Milk Feeding measures had moderate agreement when compared to medical record review, the numerator status reliability was poor for Elective Delivery, but near perfect for Exclusive Breast Milk Feeding. Improvements in eCQM data capture of some key data elements would greatly improve the reliability.
Related Concept Videos
Methods of Documentation V: CBE
In CBE, healthcare professionals establish predefined standards of practice that define what constitutes...
Methods of Documentation VII: EMR
Guidelines for Nursing Documentation I
Factual:
The following points emphasize the significance of upholding accurate and unbiased documentation in healthcare.
Data Reporting and Recording

