Related Experiment Video
Updated: Oct 9, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Splenic, hepatic, renal and pulmonary clearance dysfunction associated with high-energy X-rays
Fernando P de Faria1,2, Andy Petroianu2, Luciene G Mota3
1Departamento de Engenharia Nuclear, Universidade Federal de Minas Gerais, Belo Horizonte, Brasil.
Purpose:
To verify the high-energy X-rays effects on the blood clearance of colloidal particles by the spleen, liver, kidneys, and lungs.
Materials And Methods:
Seventeen male Wistar rats were distributed into three groups. Group 1 (n = 5) - control - non-irradiated animals, group 2 (n = 6) - irradiated animals studied 24 h after irradiation, and group 3 (n = 6) - irradiated animals studied 48 h after irradiation. The animals were anesthetized and irradiated with a non-fractionated 8 Gy dose in the abdominal region divided into two parallel and opposite fields, 4 Gy was given to the anteroposterior and 4 Gy to the posteroanterior. This high dose of high-energy X-rays causes extensive cell killing, tissue disorganization and break down cell to cell communication. According to the groups, 50 µCi of technetium-phytate were injected into the right internal jugular vein. After 30 minutes, the liver, spleen, kidneys, and lungs were removed. The clot was harvested from the abdominal cavity two minutes after the sectioning of the abdominal aorta and cava vein. The organs and clot were placed into plastic flasks to be weighed and studied for the emission of radioactivity in a gamma radiation detector. The uptake function of each organ was calculated based on the count of gamma rays emitted per minute and normalized with the organ mass, having as a reference the radioactivity count of a standard sample. The arithmetic mean of each organ uptake was calculated and compared among the groups.
Results:
After irradiation, the spleen uptake of colloidal radiopharmaceutical was greater, while the hepatic, renal, and pulmonary uptake were lower. The renal uptake decreased slower than the hepatic and pulmonary uptake.
Conclusions:
A single high dose of high-energy X-rays enhances the splenic clearance function, while it reduces the hepatic, renal, and pulmonary clearance until 48 h after irradiation, with a rapid deterioration of the hepatic and pulmonary uptake function.
Related Concept Videos
Hepatic Drug Clearance: Restrictive and Nonrestrictive Clearance
Most drugs undergo restrictive clearance, which is proportional to the...
Effect of Hepatic Disease on Pharmacokinetics: Drug Dosing and Hepatic Blood Flow
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

