Related Experiment Video
Updated: Oct 9, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Features of new vision-incorporated third-generation video laryngeal mask airways
André A J Van Zundert1, Stephen P Gatt2, Tom C R V Van Zundert3
1Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women's Hospital, The University of Queensland, Brisbane, QLD, Australia.
Abstract:
Numerous studies have shown that blindly inserted supraglottic airway devices (SADs) are sub-optimally placed in 50 to 80% of all cases. Placement under direct vision has been recommended. We describe the very first two new SADs of the third generation that incorporate a videoscope with flexible tip. Both devices are made up of two interlocking components-the SAD and a videoscope. The 3rd generation, direct vision SADs allow vision-guided insertion, corrective manoeuvres, if needed, and correct placement in the hypopharynx and possess additional features which permit insertion of a gastric tube and endotracheal intubation should the need arise. This article describes the two new devices' physical characteristics, features, rationale for use, advantages and limitations in comparison to existing devices. Each of the two new devices-the Video Laryngeal Mask (VLMTM, UE Medical®) and the SafeLM® Video Laryngeal Mask System (SafeLMTM VLMS, Magill Medical Technology®) consist of two parts: (a) a disposable 2nd generation SAD with a silicone cuff and an anatomically curved tube; and (b) a reusable patient-isolated videoscope and monitoring screen, with the flexible scope located into a specially-designed, blind-end channel terminating in the bowl of the SAD, preventing the videoscope from contacting patient body fluids in the SAD bowl. Third generation placement-under-direct-vision supraglottic airway devices possess several theoretical safety and ease of use advantages which now need to be validated in clinical use.
More Related Videos
03:58Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...