Dose Uniformity of Loteprednol Etabonate (Submicron) Ophthalmic Gel 0.38% Compared with Prednisolone Acetate
Zora T Marlowe1, Megan E Cavet2, Martin J Coffey3
1Pharmaceutical Development, R&D, Bausch + Lomb, 1400 North Goodman St, Rochester, NY, 14609, USA. Zora.Marlowe@bausch.com.
Introduction:
Loteprednol etabonate (submicron) ophthalmic gel 0.38% (LE SM gel 0.38%) is a corticosteroid formulation designed to retain the nonsettling characteristics of loteprednol etabonate ophthalmic gel 0.5%, but with reduced drug particle size to improve ocular penetration, allowing for reduced dosing frequency. This study compared the dose uniformity of LE SM gel 0.38% with branded and generic prednisolone acetate (PA) 1% suspensions under simulated in-use dosing conditions.
Methods:
Drug concentrations in drops of LE SM gel 0.38% and PA 1% suspensions, expressed from bottles that were shaken or not shaken, were determined during 2 weeks of simulated on-label dosing (LE SM gel 0.38%: three times daily; PA suspensions: four times daily). Sedimentation of drug particles was assessed for each product using dispersion analysis.
Results:
The mean (SD) percent declared drug concentration of LE SM gel 0.38% over 2 weeks was 103.2% (1.3%) when the drug was dispensed from shaken bottles and 103.3% (1.5%) when dispensed from unshaken bottles. However, for branded and generic PA suspensions, mean (SD) percent declared concentrations were 102.2% (1.4%) and 98.3% (2.9%), respectively, when dispensed from shaken bottles; and 89.2% (18.6%) and 78.3% (13.5%), respectively, when dispensed from unshaken bottles. Dispersion analysis showed that drug particles in LE SM gel 0.38% remained fully suspended under accelerated sedimentation conditions, whereas both branded and generic PA suspension drug particles settled out of suspension.
Conclusions:
LE SM gel 0.38% delivered the drug consistently at the declared concentration over the entire 2 weeks of simulated in-use dosing conditions, regardless of whether the drug was dispensed from shaken or unshaken bottles. However, both branded and generic PA suspensions required the bottle to be shaken to provide a consistent drug concentration.
Related Concept Videos
Pharmaceutical Alternatives: Polymorphic Form-Related and Particle Size-Related Therapeutic Nonequivalence
Bioequivalence: Overview
Pharmaceutical Alternatives: Stability-Related Therapeutic Nonequivalence
Formulation and Manufacturing Process: Physical Attributes of Generic Tablets and Capsules
Pharmaceutical Alternatives: Excipients and Impurities-Related Therapeutic Nonequivalence
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...