An MRI sequence independent convolutional neural network for synthetic head CT generation in proton therapy
Lukas Zimmermann1, Barbara Knäusl2, Markus Stock3
1Medical University of Vienna, Department of Radiation Oncology, Vienna, Austria; Faculty of Engineering, University of Applied Sciences Wiener Neustadt, Austria; Competence Center for Preclinical Imaging and Biomedical Engineering, University of Applied Sciences Wiener Neustadt, Austria.
Abstract:
A magnetic resonance imaging (MRI) sequence independent deep learning technique was developed and validated to generate synthetic computed tomography (sCT) scans for MR guided proton therapy. 47 meningioma patients previously undergoing proton therapy based on pencil beam scanning were divided into training (33), validation (6), and test (8) cohorts. T1, T2, and contrast enhanced T1 (T1CM) MRI sequences were used in combination with the planning CT (pCT) data to train a 3D U-Net architecture with ResNet-Blocks. A hyperparameter search was performed including two loss functions, two group sizes of normalisation, and depth of the network. Training outcome was compared between models trained for each individual MRI sequence and for all sequences combined. The performance was evaluated based on a metric and dosimetric analysis as well as spot difference maps. Furthermore, the influence of immobilisation masks that are not visible on MRIs was investigated. Based on the hyperparameter search, the final model was trained with fixed features per group for the group normalisation, six down-convolution steps, an input size of 128×192×192, and feature loss. For the test dataset for body/bone the mean absolute error (MAE) values were on average 79.8/216.3Houndsfield unit (HU) when trained using T1 images, 71.1/186.1HU for T2, and 82.9/236.4HU for T1CM. The structural similarity metric (SSIM) ranged from 0.95 to 0.98 for all sequences. The investigated dose parameters of the target structures agreed within 1% between original proton treatment plans and plans recalculated on sCTs. The spot difference maps had peaks at ±0.2cm and for 98% of all spots the difference was less than 1cm. A novel MRI sequence independent sCT generator was developed, which suggests that the training phase of neural networks can be disengaged from specific MRI acquisition protocols. In contrast to previous studies, the patient cohort consisted exclusively of actual proton therapy patients (i.e. "real-world data").
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:48PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging