Related Experiment Video
Updated: Oct 9, 2025

Magnetic Resonance Imaging Assessment of Carcinogen-induced Murine Bladder Tumors
Published on: March 29, 2019
Role of Vesical Imaging-Reporting and Data System in predicting muscle-invasive bladder cancer: A diagnostic
Baorui Yuan1, Lingkai Cai1, Qiang Cao1
1Department of Urology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
Abstract:
The objective of this study is to systematically evaluate the diagnostic performance of the Vesical Imaging-Reporting and Data System for predicting muscle-invasive bladder cancer. Embase, PubMed and Web of Science were systematically searched from 1 September 2018 to 30 July 2021 to include proper studies. We included studies that included data on Vesical Imaging-Reporting and Data System and their associated pathological findings, and we assessed their quality using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The pooled sensitivity and specificity were calculated and plotted using hierarchical summary receiver operating characterisijutic modeling. Meta-regression analysis was carried out to detect heterogeneity. A total of 20 studies with 2725 patients were included. When the cut-off point was 3, the pooled sensitivity and specificity were 0.92 (0.89-0.94) and 0.85 (0.78-0.90), respectively, and 0.82 (0.75-0.88) and 0.95 (0.91-0.97), respectively, when the cut-off point was 4. The area under the curve was 0.95 and 0.95, respectively. Heterogeneity was substantially considerable in sensitivity and specificity. All subgroup variables, including patient number, study design, magnetic resonance imaging field strength, number of radiologists, surgery pattern, diffusion-weighted imaging, and dynamic contrast-enhanced magnetic resonance imaging, contributed to sensitivity heterogeneity when the cut-off point was 3 and specificity heterogeneity when the cut-off point was 4. Multiple image acquisition plane of diffusion-weighted imaging achieved a higher sensitivity than single image acquisition plane of diffusion-weighted imaging in both the Vesical Imaging-Reporting and Data System 3 and 4 groups, and higher specificity in the Vesical Imaging-Reporting and Data System 4 group. Another significant source of heterogeneity was the cut-off point. The diagnostic performance of the Vesical Imaging-Reporting and Data System for predicting muscle-invasive bladder cancer was excellent in both cut-off points of the Vesical Imaging-Reporting and Data System 3 and 4. Multiple image acquisition planes of diffusion-weighted imaging should be given more attention in the Vesical Imaging-Reporting and Data System.
Related Concept Videos
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies III: Computed Tomography
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care

