Related Experiment Video
Updated: Oct 9, 2025

Author Spotlight: Enhancing Accuracy and Reproducibility in Whole Bone Bending Tests
Published on: September 1, 2023
Influence of X-rays and gamma-rays on the mechanical performance of human bone factoring out intraindividual bone
Felix N Schmidt1,2, Michael Hahn1, Kilian E Stockhausen1
1Department of Osteology and Biomechanics, University Medical Center Hamburg-Eppendorf, Lottestrasse 59, 22529, Hamburg, Germany.
Abstract:
Doses of irradiation above 25 kGy are known to cause irreversible mechanical decay in bone tissue. However, the impact of irradiation doses absorbed in a clinical setting on the mechanical properties of bone remains unclear. In daily clinical practice and research, patients and specimens are exposed to irradiation due to diagnostic imaging tools, with doses ranging from milligray to Gray. The aim of this study was to investigate the influence of irradiation at these doses ranges on the mechanical performance of bone independent of inter-individual bone quality indices. Therefore, cortical bone specimens (n = 10 per group) from a selected organ donor were irradiated at doses of milligray, Gray and kilogray (graft tissue sterilization) at five different irradiation doses. Three-point bending was performed to assess mechanical properties in the study groups. Our results show a severe reduction in mechanical performance (work to fracture: 50.29 ± 11.49 Nmm in control, 14.73 ± 1.84 Nmm at 31.2 kGy p ≤ 0.05) at high irradiation doses of 31.2 kGy, which correspond to graft tissue sterilization or synchrotron imaging. In contrast, no reduction in mechanical properties were detected for doses below 30 Gy. These findings are further supported by fracture surface texture imaging (i.e. more brittle fracture textures above 31.2 kGy). Our findings show that high radiation doses (≥31.2 kGy) severely alter the mechanical properties of bone. Thus, irradiation of this order of magnitude should be taken into account when mechanical analyses are planned after irradiation. However, doses of 30 Gy and below, which are common for clinical and experimental imaging (e.g., radiation therapy, DVT imaging, CT imaging, HR-pQCT imaging, DXA measurements, etc.), do not alter the mechanical bending-behavior of bone.
More Related Videos
04:24Proper Positioning and Restraint of a Rat Hind Limb for Focused High Resolution Imaging of Bone Micro-architecture Using In Vivo Micro-computed Tomography
Published on: November 22, 2017
08:43Imaging of the Microstructural Failure Mechanism in the Human Hip
Published on: September 29, 2023
Related Concept Videos
X-ray Imaging
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
The Bone Matrix