Related Experiment Video
Updated: Oct 9, 2025

Coulomb Explosion Imaging as a Tool to Distinguish Between Stereoisomers
Published on: August 18, 2017
Multi-CRAFTI: Relative Collision Cross Sections from Fourier Transform Ion Cyclotron Resonance Mass Spectrometric
Brigham L Pope1, Daniel Joaquin1, Jacob T Hickey1
1Department of Chemistry and Biochemistry, Brigham Young University, Provo, Utah 84602-1030, United States.
Abstract:
Determination of collision cross sections (CCS) using the cross-sectional areas by the Fourier transform ion cyclotron resonance (CRAFTI) technique is limited by the requirement that accurate pressures in the trapping cell of the mass spectrometer must be known. Experiments must also be performed in the energetic hard-sphere regime such that ions decohere after single collisions with neutrals; this limits application to ions that are not much more massive than the neutrals. To mitigate these problems, we have resonantly excited two (or more) ions of different m/z to the same center-of-mass kinetic energy in a single experiment, subjecting them to identical neutral pressures. We term this approach "multi-CRAFTI". This facilitates measurement of relative CCS without requiring knowledge of the pressure and enables determination of absolute CCS using internal standards. Experiments with tetraalkylammonium ions yield CCS in reasonable agreement with the one-ion-at-a-time CRAFTI approach and with ion mobility spectrometry (IMS) when differences in collision energetics are taken into account (multi-CRAFTI generally yields smaller CCS than does IMS due to the higher collision energies employed in multi-CRAFTI). Comparison of multi-CRAFTI and IMS results with CCS calculated from structures computed at the M06-2X/6-31+G* level of theory using projection approximation or trajectory method values, respectively, indicates that the computed structures have CCS increasingly smaller than the experimental CCS as m/z increases, implying the computational model overestimates interactions between the alkyl arms. For ions that undergo similar collisional decoherence processes, relative CCS reach constant values at lower collision energies than do absolute CCS values, suggesting a means of increasing the accessible upper m/z limit by employing multi-CRAFTI.
Related Concept Videos
Mass Analyzers: Common Types
High-Resolution Mass Spectrometry (HRMS)
Mass Analyzers: Overview
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Mass Spectrometers
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...

