Does the use of BariBoard™ improve adequacy of chest compressions in morbid obesity? A pilot study using a simulation
Kate Goulding1, Rosa Marchetti1, Rushan Perera2
1Member of the Australasian College for Emergency Medicine, Australia; Alice Springs Hospital, Gap Road, Alice Springs, Northern Territory, Australia.
Background:
Obesity is a growing health problem worldwide. Morbid obesity has been associated with significant barriers to effective thoracic cage compression during cardiopulmonary resuscitation.
Objective:
The BariBoard™ purports to improve adequacy of chest compressions in morbidly obese patients. This study uses a simulation model to evaluate this.
Methods:
This was a prospective blinded randomised-controlled crossover pilot trial using a simulation model of obesity. Participants, recruited from hospital departments and prehospital services, performed 2 minutes of continuous compressions on mannequins modified to emulate a morbidly obese patient. Participants were randomised by coin toss to a sequence of either control/intervention or intervention/control, with the BariBoard™ in the intervention arm. Accelerometers measured chest wall movement during compressions. The primary endpoint was a composite measure of compression adequacy (rate, depth, and recoil). Secondary endpoints comprised the individual components of the composite outcome, as both dichotomous outcomes (adequate vs. inadequate) and continuous variables. All endpoints were adjusted for potential confounders.
Results:
Of 205 participants recruited, 201 were analysed. There was a significant difference in the primary outcome between the control and intervention arms (13.4% vs. 4.5%, respectively, p = 0.001) and between the control and intervention arms for the secondary endpoints of adequate compression depth (31.3% vs. 15.9%, p < 0.001) and recoil (63.7% vs. 41.3%, p < 0.001). After adjustment for confounders and interactions, there was no difference in overall efficacy (odds ratio: 0.62, 95% confidence interval: 0.20-1.90, p = 0.40).
Conclusion:
This pilot study describes the successful assessment of a device using a simulation model of obesity. Within these constraints and after adjustment for confounders, use of the BariBoard ™ did not improve efficacy of chest compressions.
Related Concept Videos
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
Pneumothorax-II
Clinical Manifestations:
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Drug Dosing: Obese Patients
Cardiopulmonary Resuscitation I: Adult