Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Using noninvasive adjusted pulse transit time for tracking beat-to-beat systolic blood pressure during ventricular
Fen Miao1, Bin Zhou2,3, Zengding Liu1
1Key Laboratory for Health Informatics, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
Abstract:
Tracking beat-to-beat blood pressure noninvasively during ventricular arrhythmia (VA) is of great importance but rarely reported. The goal of our study was to investigate the potential utility of the adjusted pulse transit time (APTT) to track beat-to-beat femoral systolic blood pressure (SBP) during VA. Patients who underwent radiofrequency ablation for arrhythmias at Fuwai Hospital were enrolled. Electrocardiograms (ECGs), finger photoplethysmograms, and femoral arterial blood pressure were recorded simultaneously during VA. The APTT was calculated as the ratio between the square of the conventional pulse transit time (cPTT) and the RR interval of the ECG waveform. Forty-five patients were enrolled in our study, and 22,849 beats were collected during their VA. The inverse of the APTT showed a good correlation with femoral SBP during VA (r = 0.70 ± 0.18). The APTT-derived SBP demonstrated acceptable accuracy in terms of the mean difference ± standard deviation (-0.01 ± 10.54 mmHg) from the invasive femoral SBP. The area under the receiver operating characteristic (ROC) curve for the ability of the APTT to detect ≥30% decreases in femoral SBP was 0.903 (95% confidential interval, 0.895-0.911). In addition, the APTT performed better than the cPTT and RR interval in the above analysis (all P < 0.05). Therefore, the APTT has acceptable accuracy in tracking beat-to-beat femoral SBP and could detect substantially decreased femoral SBP. These findings indicate that the APTT may be a promising noninvasive surrogate for invasive femoral SBP during VA. A multiparameter model combining APTT and other parameters is needed to further improve the accuracy.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse
The pulse serves as a clinical...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...