Related Experiment Video
Updated: Oct 9, 2025

Murine Fetal Echocardiography
Published on: February 15, 2013
Echocardiographic findings for improved prenatal diagnosis of aortic coarctation with ventricular septal defect
Yunyu Chen1, Huixian Li2, Danping Huang1
1Department of Medical Ultrasonics, Guangzhou Women and Children's Medical Center, Guangzhou Medical University, NO.9 of Jinsui Road, Guangzhou, 510623, China.
Insights
Accurate prenatal diagnosis of coarctation of the aorta (CoA) with ventricular septal defect (VSD) is improved using spectral Doppler metrics. Combining these with the aortic isthmus Z score enhances diagnostic accuracy and reduces false positives in fetal assessments.
Area of Science:
- Fetal Cardiology
- Diagnostic Imaging
- Congenital Heart Defects
Background:
- Prenatal diagnosis of coarctation of the aorta (CoA) associated with ventricular septal defect (VSD) presents significant challenges.
- Accurate identification of these fetal cardiac anomalies is crucial for timely intervention and improved outcomes.
- Existing sonographic methods require refinement for enhanced predictive capability.
Purpose of the Study:
- To identify sonographic findings, particularly Doppler-derived metrics, that are most effective in predicting fetal CoA associated with VSD.
- To evaluate the diagnostic performance of quantitative spectral Doppler measurements in conjunction with conventional imaging parameters.
- To improve the accuracy of prenatal diagnosis for CoA/VSD, thereby reducing false positive rates.
Main Methods:
- Retrospective cohort study of 35 fetuses with suspected CoA/VSD.
- Analysis of prenatal imaging characteristics including right/left ventricular ratio, pulmonary artery/aorta ratio, aortic isthmus (AOI) Z score, and diastolic (VTID) and systolic (VTIS) velocity-time integrals at the AOI.
- Statistical evaluation using receiver operating characteristic curves (AUC), integrated discrimination improvement (IDI), and net reclassification improvement (NRI).
Main Results:
- Significant differences were observed in PA/AO ratio, VTID, VTID/VTIS, and AOI Z score between true CoA and false positive groups.
- The VTID/VTIS and VTID/(VTID + VTIS) metrics demonstrated high diagnostic performance (AUC 0.97) for CoA when associated with VSD.
- Combining the VTID/VTIS metric with the AOI Z score significantly improved diagnostic accuracy (IDI 50%, NRI 82%), enhancing specificity without compromising sensitivity.
Conclusions:
- Quantitative spectral Doppler metrics, specifically VTID/VTIS and VTID/(VTID + VTIS), are valuable tools for accurate prenatal detection of fetal CoA associated with VSD.
- The integration of these spectral Doppler findings with the conventional AOI Z score offers a more robust approach to diagnosing CoA/VSD.
- This combined approach aids in accurate fetal CoA detection, leading to a reduction in false positives and improved diagnostic precision.
Abstract:
Accurate prenatal diagnosis of coarctation of the aorta (CoA) associated with ventricular septal defect (VSD) remains challenging. The objective of the study was to identify which Doppler and/or two-dimensional sonographic findings are most useful for predicting fetal CoA/VSD. A retrospective cohort study identified 35 fetuses with suspected CoA/VSD. Prenatal imaging characteristics included the right ventricular/left ventricular, pulmonary artery (PA)/aorta ratio, aortic isthmus (AOI) Z score, diastolic velocity-time integral (VTID), and systolic velocity-time integral (VTIS) at the AOI. The area under the receiver operating characteristic curve (AUC), integrated discrimination improvement (IDI), and net reclassification improvement (NRI) were calculated. Significant differences in the PA/AO, VTID, VTID/VTIS, VTID/VTIS, VTID/(VTID + VTIS), and AOI Z score between the true CoA group and false positives were found. When associated with VSD, the VTID/VTIS and VTID/(VTID + VTIS) had the highest AUC (0.97, 95% confidence interval: 0.84-1.00), with 88.46% sensitivity and 100.00% specificity for predicting the true CoA. The AOI Z score had the highest sensitivity (92.31%). Adding the VTID/VTIS to the AOI Z score significantly improved the performance (IDI, 50%; NRI, 82%; P < 0.05), with an improvement in specificity (77.78% vs. 55.56%; non-Event P = 0.008) without sacrificing sensitivity (96.15% vs. 92.31%; Event P = 0.564). In fetuses with suspected CoA associated with VSD, the quantitative spectral Doppler metric aided accurate detection of the fetal CoA, with reduced false positives. The conventional AOI Z score plus spectral Doppler metric may improve the overall diagnostic accuracy of CoA/VSD.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Aortic Regurgitation I: Introduction
Mitral Regurgitation II: Clinical Features and Diagnostic Tests

