Where can you wear your Libre? Using the FreeStyle Libre continuous glucose monitor on alternative sites
Rosemary M Hall1,2, Sophie Dyhrberg3, Arthur McTavish3
1Endocrine, Diabetes and Research Centre, Wellington Regional Hospital, Wellington, New Zealand.
Aim:
To investigate the accuracy and acceptability of the FreeStyle Libre Flash continuous glucose monitoring system (FSL-CGM) at alternative sites during free living and under experimental conditions.
Materials And Methods:
Participants with type 1 diabetes were provided with three FSL-CGM sensors applied to the upper arm, the lower back, and the anterior chest. On day 2 or 3, FSL-CGM sensor glucose was compared with venous glucose following a standard meal, during and after an exercise test, and after skin cooling. Participants completed 14-day use of the sensors with concomitant sensor scanning at all sites and capillary glucose tests. The primary outcome was accuracy between sensor sites of 14-day mean glucose. Clarke's error grids, precision absolute relative deviation, and mean absolute relative deviation were calculated.
Results:
In the 20 participants, compared with the arm sensor, the accuracy of the back sensor and the chest sensor was 97.9% and 98%, respectively. Under experimental conditions, the arm sensor was more accurate than that of the back and chest. All the sensors recorded higher glucose concentration than venous samples during exercise. The arm and chest sites were most preferred, with the greatest sensor failures from the back.
Conclusions:
The FSL-CGM is clinically accurate when the sensors are applied to alternate chest or back sites. Greater variability occurs during rapid changes in glucose concentration with all sensor sites compared with venous glucose. Understanding these variabilities allows appropriate use of an economically viable continuous glucose monitor.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Assessment Sites
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Holter Monitor: 24-Hour Monitoring
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...