Related Experiment Video
Updated: Oct 9, 2025

Assessment of Vascular Function in Patients With Chronic Kidney Disease
Published on: June 16, 2014
Blood Pressure Variability in Fabry Disease Patients
Mevlut Tamer Dincer1, Seyda Gul Ozcan2, Baris Ikitimur3
1Department of Nephrology, Cerrahpasa Medical Faculty, Istanbul University - Cerrahpasa, Istanbul, Turkey.
Introduction:
Fabry disease is a rare metabolic, multisystemic, and X-linked lysosomal storage disorder. The involvement of the autonomic nervous system is well defined; however, data on the variability of the blood pressure (BP) and heart rate in Fabry disease are largely missing. In this study, we aimed to examine the circadian variations of BP and heart rate variability in Fabry disease patients.
Methods:
We recruited 31 consecutive adult (age >18 years) Fabry disease patients (16 males and 15 females) who were regularly followed up in our outpatient clinic between July 2019 and March 2020. We performed ambulatory blood pressure monitoring and echocardiography in all patients. We used standard deviation (SD), coefficient of variation (CV), and average real variability as the measures of variability. We constructed 2 control groups for propensity score matching using age, sex, and eGFR parameters in the first group and adding antihypertensive drug use to the above parameters in the second group.
Results:
All BP measurements were significantly lower in the FD group compared to that of the control groups, except the nighttime systolic BP. Regarding nondipping and reverse dipping statuses, FD patients and controls were similar. We found that none of the BP variability measures were higher in FD patients. Regarding heart rate variability data, both the nighttime SD and CV were significantly lower in FD patients compared to those of the controls.
Conclusion:
A decrease in heart rate variability, rather than an increase in BP variability, might be an early marker of autonomic involvement in FD.
More Related Videos
08:42Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
10:16In Vitro Enzyme Measurement to Test Pharmacological Chaperone Responsiveness in Fabry and Pompe Disease
Published on: December 20, 2017
Related Concept Videos
Measurement of Blood Pressure
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Factors affecting Blood pressure
Physiological Factors:
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: