Related Experiment Video
Updated: Oct 9, 2025

A Reference Broth Microdilution Method for Dalbavancin In Vitro Susceptibility Testing of Bacteria that Grow Aerobically
Published on: September 9, 2015
A simple disk pre-diffusion test to predict in vitro aztreonam/avibactam activity against NDM-producing Klebsiella
Keila de Oliveira Lima1, Aline Valério de Lima1, Darlan Augusto da Costa Rocha2
1Antimicrobial Resistance and Clinical Microbiology Laboratory, University of São Paulo, School of Pharmacy, São Paulo, SP, Brazil.
Objectives:
The aim of this study was to describe a simple test to predict in vitro efficacy of aztreonam/avibactam (ATM-AVI) combination based on a pre-diffusion assay involving routinely available ceftazidime/avibactam (CAZ-AVI) and aztreonam (ATM) disks.
Methods:
A total of 113 non-repetitive NDM-producing Klebsiella had the species identified by multiplex PCR. Minimum inhibitory concentrations (MICs) for ATM and ATM-AVI were determined by broth microdilution. For the combined disk pre-diffusion method, a disk containing ceftazidime 10 μg and avibactam 4 μg (CAZ-AVI) was applied on the surface of an uninoculated Mueller-Hinton agar plate. Following incubation for 2 h at 36°C, the disk was removed, the bacterial suspension was applied and a 30 μg ATM disk was placed precisely in the same position as the removed CAZ-AVI disk. Following incubation for 16-20 h, inhibition zone diameters were measured and correlated with ATM-AVI MICs.
Results:
The distribution of species among the 113 isolates was 85 Klebsiella pneumoniae (75.2%), 19 Klebsiella quasipneumoniae (16.8%) and 9 Klebsiella variicola (8.0%). A total of 99 isolates had only blaNDM and 14 had both blaNDM and blaKPC genes. Regarding the isolates positive for blaNDM only, 38.4% were susceptible to ATM and 7.1% were susceptible, increased exposure. All isolates had ATM-AVI MICs of ≤1 mg/L, and the smallest inhibition zone diameter observed was 23 mm.
Conclusion:
Modified disk pre-diffusion can be used as a simple test to screen for ATM-AVI in vitro activity against Klebsiella, since ATM-AVI disks, gradient strips or microdilution panels are not commercially available.
More Related Videos
12:03Antimicrobial Synergy Testing by the Inkjet Printer-assisted Automated Checkerboard Array and the Manual Time-kill Method
Published on: April 18, 2019
11:25Preparation of a Blood Culture Pellet for Rapid Bacterial Identification and Antibiotic Susceptibility Testing
Published on: October 15, 2014