Volatile Compounds in Pulses: A Review
Adeline Karolkowski1,2, Elisabeth Guichard1, Loïc Briand1
1CSGA (Centre des Sciences du Goût et de l'Alimentation), AgroSup Dijon, CNRS, INRAE, Université de Bourgogne-Franche Comté, 21000 Dijon, France.
Foods (Basel, Switzerland)
|December 24, 2021
Summary
Growing demand for pulses is hindered by undesirable "beany" off-flavors. Understanding volatile compounds causing these off-notes is key to improving pulse acceptability in healthy foods.
Area of Science:
- Food Science
- Sensory Science
- Analytical Chemistry
Background:
- Increasing global demand for pulse-based foods for health and sustainability.
- Limited consumer acceptability of pulses due to off-flavors, commonly described as 'beany' notes.
- Off-flavors originate from volatile compounds produced during seed development, storage, and processing.
Purpose of the Study:
- To review the identification and origins of volatile compounds responsible for off-notes in pulses.
- To highlight the impact of these compounds on consumer perception.
- To identify knowledge gaps regarding odor-active compounds in pulses.
Main Methods:
- Literature review focusing on studies identifying volatile compounds in pulses.
- Analysis of the chemical classes and origins of these volatile compounds.
- Examination of the link between specific volatile compounds and sensory perceptions.
Main Results:
- Volatile compounds contributing to off-notes are diverse and arise from fatty acid oxidation and amino acid degradation.
- Data on odor-active compounds in pulses are scarce, with limited research on peas and lupins.
- Understanding these compounds is crucial for developing strategies to mitigate negative sensory impacts.
Conclusions:
- Further research is needed to comprehensively identify volatile compounds and their pathways in various pulses.
- Targeted strategies can be developed to reduce off-flavors, enhancing the appeal of pulse-based foods.
- Improved knowledge will support the design of more acceptable and healthier food products.
Related Concept Videos
Volatilization
603
Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
603
Regulation of Pulse
1.6K
Pulse regulation involves physiological mechanisms that ensure adequate blood flow throughout the body. The heartbeat, regulated by the autonomic nervous system, is influenced by hormonal balance, physical activity, and emotional state.
1.6K
Vapor Pressure
36.4K
When a liquid vaporizes in a closed container, gas molecules cannot escape. As these gas phase molecules move randomly about, they will occasionally collide with the surface of the condensed phase, and in some cases, these collisions will result in the molecules re-entering the condensed phase. The change from the gas phase to the liquid is called condensation. When the rate of condensation becomes equal to the rate of vaporization, neither the amount of the liquid nor the amount of the vapor...
36.4K
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
973
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
973
Voltammetric Techniques: Pulse Voltammetry
739
Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
739
Special considerations while measuring pulse
667
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
667


