Related Experiment Video
Updated: Oct 9, 2025

Real-Time Proxy-Control of Re-Parameterized Peripheral Signals using a Close-Loop Interface
Published on: May 8, 2021
A First Step towards a Comprehensive Approach to Harmonic Analysis of Synchronous Peripheral Volume Pulses: A
Hsien-Tsai Wu1, Bagus Haryadi1,2, Jian-Jung Chen3,4
1Department of Electrical Engineering, National Dong Hwa University, No. 1, Sec. 2, Da Hsueh Rd., Hualien 97401, Taiwan.
Abstract:
The harmonic analysis (HA) of arterial radial pulses in humans has been widely investigated in recent years for clinical applications of traditional Chinese medicine. This study aimed at establishing the validity of carrying out HA on synchronous peripheral volume pulses for predicting diabetes-induced subtle changes in heart energy. In this study, 141 subjects (Group 1: 63 healthy elderly subjects; Group 2: 78 diabetic subjects) were enrolled at the same hospital. After routine blood sampling, all synchronous electrocardiogram (ECG) and photoplethysmography (PPG) measurements (i.e., at the six locations) were acquired in the morning. HA of synchronous peripheral volume pulses and radial pulse waves was performed and analyzed after a short period of an ensemble averaging process based on the R-wave peak location. This study utilized HA for the peripheral volume pulses and found that the averaged total pulse energy (i.e., the C0 of the DTFS) was identical in the same subject. A logistic regression model with C0 and a waist circumference variable showed a graded association with the risk of developing type 2 diabetes. The adjusted odds ratio for C0 and the waist circumference were 0.986 (95% confidence interval: 0.977, 0.994) and 1.130 (95% confidence interval: 1.045, 1.222), respectively. C0 also showed significant negative correlations with risk factors for type 2 diabetes mellitus, including glycosylated hemoglobin and fasting plasma glucose (r = -0.438, p < 0.001; r = -0.358, p < 0.001, respectively). This study established a new application of harmonic analysis in synchronous peripheral volume pulses for clinical applications. The findings showed that the C0 could be used as a prognostic indicator of a protective factor for predicting type 2 diabetes.
More Related Videos
08:32Assembly and Characterization of an External Driver for the Generation of Sub-Kilohertz Oscillatory Flow in Microchannels
Published on: January 28, 2022
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
Related Concept Videos
Effective Value of a Periodic Waveform
The effective value of a periodic current represents the direct current (DC) that conveys the same average power to a resistor as the periodic current itself. This concept is crucial when assessing AC circuits. To determine the...
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
Harmonic Mean
Take the example of the speed of a car, which is the measure of the rate of distance traveled. If the vehicle traverses the same distance back-and-forth, its average speed equals the total distance traveled divided by the total time taken. However, if the car moves with varying speeds, then the arithmetic mean is more skewed...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...
Generation of Three-Phase Voltage
As the rotor...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...