O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
NIR spectroscopic methods for monitoring blend potency in a feed frame - calibration transfer between offline and
Yuxiang Zhao1, Shikhar Mohan1, Kandarp Dave1
1Duquesne University, Pittsburgh, PA 15282, United States.
Abstract:
A material sparing method for near-infrared (NIR) calibration was developed using an offline apparatus coupled with a calibration transfer method to enable a partial least squares (PLS) model to monitor the concentration of active pharmaceutical ingredients (API) in the feed frame of a rotary tablet press. The offline apparatus was designed to simulate the powder flow dynamic and NIRS measurement environment of a tablet-press feed frame. A comprehensive experimental design, including calibration and testing, was employed to determine blend inhomogeneity. NIR spectra were collected at both the feed frame (inline) conditions and the simulator (offline) conditions. The simulator conditions were designed to mimic the density and powder flow in the feed frame during the actual tableting process. The offline data were pretreated by an orthogonalization-based calibration transfer algorithm, a continuum regression filter (CR filter), before being subjected to PLS modeling. This study demonstrated: (1) calibration for inline application can be generated using an offline apparatus, and (2) the CR filter, as an innovative calibration transfer method, can generalize the offline method for multiple feed frame conditions.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
IR Spectrometers
UV–Vis Spectrometers
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...