Related Experiment Video
Updated: Oct 8, 2025

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Correlations Among Consistency, Computed Tomography Values, and Histopathological Subtypes of Spinal Meningioma
Tatsuro Aoyama1,2, Toshihiro Ogiwara1, Kiyoshi Ito1
1Department of Neurosurgery, Shinshu University School of Medicine.
Abstract:
The consistency of spinal meningiomas is important to consider when performing tumor removal surgery. This study evaluated the correlations between spinal meningioma consistency and both preoperative computed tomography (CT) values and histopathological subtypes. Fifteen consecutive patients who underwent surgical resection of spinal meningioma at our institution were identified, and preoperative CT values and the signal intensity of T2-weighted magnetic resonance images of the tumor were determined retrospectively. The consistency of the spinal meningioma was defined based on the ultrasonic surgical aspirator output during tumor debulking. Patients were assigned to 2 groups: a soft group (n=4) and a hard group (n=11). The T2 signal intensity was significantly higher in the soft group than in the hard group (p=0.001). While the CT values were considerably higher in the hard group, the difference was not significant (p=0.19). Regarding the histopathological subtypes, psammomatous meningioma exhibited significantly higher CT values than meningothelial meningioma (p=0.019); however, there was a higher frequency of hard tumors in meningothelial meningioma cases than in psammomatous meningioma cases. Although neither robust correlations between tumor consistency and CT values nor a relationship between tumor consistency and histopathological subtype has been established, these results might help with the perioperative manegement of spinal tumors.
Related Concept Videos
Imaging Studies III: Computed Tomography
Cranial and Spinal Meninges
Cranial Meninges
These meningeal layers cover the cranium. The dura mater is the outermost layer of cranial meninges. It is a thick and durable membrane of dense...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

