Related Experiment Video
Updated: Oct 8, 2025

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
Published on: June 3, 2020
The Transosseous Internal Four Strand Technique: A New All-Inside Technique for Zone 1 Flexor Tendon Repairs
Patrick S Harenberg1,2, Jörg G Grünert2, Samuel M Christen2
1BG University Hospital Bergmannsheil Bochum, Germany.
Background:
Multiple techniques for the repair of flexor tendon injuries in zone 1 have been proposed over time. While pull-out suture techniques and bone anchor seem to be stronger than internal suture techniques, they are associated with a higher complication rate. We therefore developed an alternative internal suture repair with similar biomechanical stability to those of pull-out sutures and bone anchors.
Methods:
Twenty porcine distal phalanges and deep flexor tendons were randomized to 2 groups of 10 each. The tendons were transsected at the level of the distal interphalangeal joint. In group 1, repairs were performed with a well-established intraosseous suture repair and in group 2 with our new multistrand technique. The repairs were biomechanically tested with linear distraction until failure.
Results:
We recorded a significantly higher 2-mm gap force (2GF)-and thus higher stability-of the repairs in group 1 in comparison to group 2. With a 2GF of more than 50 N, our suture technique allows for a modern early active motion rehabilitation protocol. Breakage of the suture construct occurred at random places in the repair in both groups. No pull-outs were noted.
Conclusions:
This study presents a strong transosseous multistrand repair technique for flexor tendon repair in zone 1 that is simple and fast to perform and should have enough strength to withstand early active motion rehabilitation.