Visualization of Anterior Chamber Angle Structures With Scattering- and Polarization-Sensitive Anterior Segment
Yuta Ueno1, Haruhiro Mori1, Keita Kikuchi1
1Department of Ophthalmology, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan.
Purpose:
The purpose of this study was to compare three optical coherence tomography (OCT) modalities in the observation of anterior chamber angle structures; trabecular meshwork (TM), Schlemm's canal (SC), and band of extracanalicular limbal lamina (BELL).
Methods:
Three OCT modalities were used: (1) 2 × 2 Jones-matrix scattering OCT (S-OCT) representing conventional intensity OCT, (2) polarization-diverse S-OCT that was calculated as summation of all elements of the Jones-matrix to eliminate the influence of artifacts caused by sample birefringence, and (3) polarization-sensitive OCT (PS-OCT) to assess depth-resolved phase retardation.
Results:
In a total of 97 eyes of 55 subjects, nasal and temporal angles were scanned. The detection rate of TM and BELL was significantly different among modalities; highest with PS-OCT (95.1% and 99.2%), followed by 2 × 2 Jones-matrix S-OCT (71.1% and 88.7%) and polarization-diverse S-OCT (33.2% and 25.0%), indicating the influence of artifacts on 2 × 2 Jones-matrix S-OCT measurements. SC was visible with 2 × 2 Jones-matrix S-OCT, polarization-diverse S-OCT, and PS-OCT in 14.2%, 14.9%, and 0.3% of images, respectively. The intergrader agreement as evaluated with the prevalence-adjusted bias-adjusted κ value was higher with PS-OCT than with other S-OCTs.
Conclusions:
Visibility of anterior chamber angle structures was assessed with three OCT modalities. For TM and BELL that are rich in collagen fibers, PS-OCT provides significantly better visibility than S-OCT without the influence of artifacts arising from polarization or birefringence. Visualization of SC was more difficult with any OCT modalities.
Translational Relevance:
PS-OCT is a useful tool to investigate the anterior chamber angle structures which are difficult to observe with conventional OCT.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...