A unique case of direct lightning strike

Ashesh Gunwantrao Wankhede1

  • 1Department of Forensic Medicine and Toxicology, Lt. BRKM Govt. Medical College, Jagdalpur, India.

Related Concept Videos

Induced Electric Fields01:23

Induced Electric Fields

The fact that emfs are induced in circuits implies that work is being done on the conduction electrons in the wires. What can possibly be the source of this work? We know that it’s neither a battery nor a magnetic field, as a battery does not have to be present in a circuit where current is induced, and magnetic fields never do any work on moving charges. The source of the work is in fact an electric field that is induced in the wires. For example, if a stationary conductor is placed in a...
4.0K
Charge on a Conductor01:26

Charge on a Conductor

An interesting property of a conductor in static equilibrium is that extra charges on the conductor end up on its outer surface, regardless of where they originate. Consider a hollow metallic conductor with a uniform surface charge density. Since the conductor itself is in electrostatic equilibrium, there should not be any electric field inside the conductor. Now, assume a Gaussian surface enclosing the hollow portion. Applying Gauss's law, the inner surface of the hollow conductor will not...
4.8K
Equipotential Surfaces and Conductors01:16

Equipotential Surfaces and Conductors

For a conductor in which all charges are at rest, the conductor's surface is equipotential. The electric field is always perpendicular to equipotential surfaces. Therefore, in a conductor with static charges, the electric field just outside the conductor is always perpendicular to the conductor's surface. Any tangential component of the electric field will cause charges to move inside the conductor, which will violate the electrostatic nature of the system. In an electrostatic...
3.8K
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
175
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
170
Charging Conductors By Induction01:15

Charging Conductors By Induction

The Earth is a good conductor of electricity, and it is so big that it can be considered an infinite source or sink of charges. It can easily exchange charges with any matter.
Generally, conductors like metals do not allow any excess charge to be present on them. Any excess charge added to metals easily flows away, for example, when a metal is placed on the Earth. This process is called earthing.
However, conductors can be charged by a process called induction. For example, consider charging a...
8.4K