Abstract:
As a colorless, highly toxic and widely used chemical reagent, phosgene poses a potentially serious threat to public health and environmental safety. Therefore, there is an urgent need to develop a simple and sensitive method for detecting phosgene. In this work, a ratiometric fluorescent probe (NED) for phosgene was developed by utilizing 4-substituted 1,8-naphthimide unit as the fluorophore and ethylenediamine as the recognition moiety. The probe NED undergoes intramolecular cyclization reaction with phosgene, resulting in a remarkable ratiometric fluorescence response. The probe NED displays high sensitivity (LOD = 4.9 nM), excellent ratiometric fluorescence signal, and high selectivity toward phosgene over other relevant analytes. In addition, paper test strip capable of visually detecting gaseous phosgene has also been fabricated.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
09:46Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
Published on: August 19, 2013
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Photoluminescence: Applications
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Fluorescence and Phosphorescence: Instrumentation