Operating room ventilation systems: recovery degree, cleanliness recovery rate and air change effectiveness in an
J L A Lans1, N M C Mathijssen2, A Bode3
1Faculty of Architecture and the Built Environment, Delft University of Technology, Delft, The Netherlands; Reinier de Graaf Hospital, Delft, The Netherlands.
Background:
Entrainment test methods are described in most European standards and guidelines to determine the protected area for ultra-clean ventilation (UCV) systems. New UCV systems, such as temperature-controlled airflow (TcAF) and controlled dilution ventilation (cDV) systems, claim the whole operating room (OR) to be ultra-clean. However, current test standards were not developed to assess ventilation effectiveness outside the standard protected area.
Aim:
To assess and compare the ventilation effectiveness of four types of OR ventilation systems in the ultra-clean area using a uniform test grid.
Methods:
Ventilation effectiveness of four ventilation systems was evaluated for three different ultra-clean (protected) areas: the standard protected area (A); the area outside the standard protected area (B); and a large protected area (AB). Ventilation effectiveness was assessed using recovery degree (RD), cleanliness recovery rate (CRR) and air change effectiveness (ACE).
Findings:
RD, CRR and ACE were significantly higher for the unidirectional air flow (UDAF) system compared with the other systems in area A. In area B, the UDAF and cDV systems were comparable for RD and CRR, and the UDAF and conventional ventilation (CV) systems were comparable for ACE. In area AB, the UDAF and cDV systems were comparable for CRR and ACE, but significant differences were found in RD.
Conclusion:
In area A, the ventilation effectiveness of the UDAF system outperformed other ventilation systems. In area B, the cDV system was best, followed by the UDAF, TcAF and CV systems. In area AB, the UDAF system was best, followed by the cDV, TcAF and CV systems.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Suctioning the Nasopharyngeal Airway
Equipment Required