Simultaneous measurement of H2O concentration and effective absorption optical path length under unknown optical path
Wei Nie1, Meirong Dong1, Jidong Lu1
1School of Electric Power, South China University of Technology, Guangzhou 510640, China.
Abstract:
Quantitative gas measurement under the condition of unknown optical path length is a challenge in laser absorption spectroscopy technology field. In this paper, we proposed a tunable diode laser absorption spectroscopy line shape analysis (TDLAS-LSA) method for simultaneous measurement of water vapor concentration and effective optical path length (EOPL) under unknown optical path conditions. A single H2O absorption line near 1383.9 nm (7226.02 cm-1) was selected, and its line strength, self-broadening coefficient and temperature-dependence coefficient were measured experimentally to improve the HITRAN databases. The Lorentz broadening and line area were accurately extracted by Hartmann-Tran profile (HTP) fitting, and the gas concentration and EOPL were calculated based on the spectral line shape analysis method. Eight concentrations of water vapor in the range of 146 ppm ∼ 4.39% were measured experimentally, and the maximum average deviation between the TDLAS-LSA method and the commercial sensor was less than 7.1%. Comparing the EOPL with mechanical measurement, the maximum deviation of multiple measurements is less than 5.7%. The results showed that the TDLAS-LSA method can effectively perform gas sensing under unknown optical path conditions, and has great application potential in low-cost, in-situ and multi-parameter simultaneous measurement.
More Related Videos
Related Concept Videos
UV–Vis Spectroscopy: Beer–Lambert Law
UV–Vis Spectrometers
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....