Related Experiment Video
Updated: Oct 8, 2025

Generic Protocol for Optimization of Heterologous Protein Production Using Automated Microbioreactor Technology
Published on: December 15, 2017
Minocycline Hydrochloride Controlled-release Microsphere Preparation Process Optimization Based on the Robust Design
Mohammad Karim Haidar1, Fumiyoshi Yamashita2, Mitsuru Hashida2
1Erzincan Binali Yıldırım University Faculty of Pharmacy, Department of Pharmaceutical Technology, Erzincan, Turkey.
Objectives:
The objective of the present study is to establish a robust preparation method that could steadily produce minocycline hydrochloride (MCH) microspheres regardless of used polymer types.
Materials And Methods:
Taguchi's Robust Experimental Design methodology was employed to optimize the process parameters for MCH-loaded poly(D,L-lactide-co-glycolide) (PLGA) microspheres. In the experimental design, seven controllable factors, i.e., preparation method, pH of the aqueous phase, volume of the aqueous phase, volume of dichloromethane, rotation speed, temperature, and amount of polyvinyl alcohol, were considered for the optimization of process parameters. PLGA types with different lactide/glycolide ratios were considered the uncontrollable (noise) factor. Based on the L18 orthogonal array, 18 experimental runs were conducted for each type of PLGA. The encapsulation efficiency (EE) and in vitro release rate were evaluated for all the prepared formulations.
Results:
Regardless of the PLGA type with different lactic/glycolic acid ratios, microspheres prepared via the solid-in-oil-in-water (S/O/W) method, showed a much higher EE and faster drug release than the microspheres prepared via the co-solvent method. Preparation methods, pH of the aqueous phase, and volume of the aqueous phase were the most influencing parameters on the EE. The confirmation experiment results indicated that the signal-to-noise ratio increased by 5.76 db from that of an initial condition. The release of minocycline was fastest with the PLGA (50:50) microspheres, followed by PLGA (75:25) and PLGA (85:15).
Conclusion:
Although the interaction between the selected factors in the evaluation was ignored, the orthogonal array design of the experiment based on Taguchi's robust experimental design methodology was sufficient to optimize the process parameters for the PLGA microspheres of MCH. The S/O/W was the main factor affecting the EE. Microspheres prepared via the S/O/W method exhibited a higher EE and faster drug release than the microspheres prepared via co-solvent method. The pH and volume of the aqueous phase were also effective parameters on the EE. A robust experimental design has been successfully applied to the optimization of the process parameters for microsphere preparation.
More Related Videos
05:45Author Spotlight: Process Development for the Spray-Drying of Probiotic Bacteria and Evaluation of the Product Quality
Published on: April 7, 2023
13:54A Workflow for Lipid Nanoparticle LNP Formulation Optimization using Designed Mixture-Process Experiments and Self-Validated Ensemble Models SVEM
Published on: August 18, 2023
Related Concept Videos
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Biopharmaceutical Factors Influencing Drug Product Design: Overview
Dosage Regimens: Designs and Approaches