Related Experiment Video
Updated: Oct 8, 2025

Optimized Management of Endovascular Treatment for Acute Ischemic Stroke
Published on: January 18, 2018
Diagnostic accuracy of using Alberta Stroke Program Early Computed Tomography Score on CT perfusion map to predict a
Yue Chu1, Guang-Chen Shen1, Gao Ma1
1Department of Radiology, First Affiliated Hospital of Nanjing Medical University, No. 300, Guangzhou Rd., Nanjing, China.
Purpose:
To assess the diagnostic accuracy of using Alberta Stroke Program Early Computed Tomography Score (ASPECTS) on CT perfusion (CTP) map to predict a volumetric target mismatch in patients with acute ischemic stroke (AIS).
Methods:
Three-hundred and seven AIS patients with an onset time within 24h or unclear onset time who underwent CTP evaluation for large vessel occlusion of anterior circulation were enrolled. CTP ASPECTS was evaluated on cerebral blood flow (CBF) and time-to-maximum (Tmax) colored maps, respectively. Automated perfusion analysis software was used to calculate the volumes of ischemic core (volumeCBF<30%) and tissue at risk (volumeTmax>6s). Target mismatch was defined as volumeCBF< 30%<70ml, volumemismatch≥15ml, and volumeTmax >6s/volume CBF< 30%≥1.8. Spearman correlation and receiver operating characteristic curves were used for statistical analyses.
Results:
Strong correlations were found between CBF ASPECTS and volumeCBF<30%, and between Tmax ASPECTS and volumeTmax>6s for overall population (ρ=-0.872, -0.757) and late-arriving patients (ρ=-0.900, -0.789). Mismatch ASPECTS moderately correlated with mismatch volume for overall population (ρ=0.498) and late-arriving patients (ρ=0.407). A CBF ASPECTS≥5 optimally predicted an ischemic core volume<70ml in overall population (sensitivity, 94.4%; specificity, 80.4%) and late-arriving patients (sensitivity, 89.5%; specificity, 90.5%). A CBF ASPECTS≥6 combined with a Mismatch ASPECTS≥1 optimally identified a target mismatch in overall population (sensitivity, 84.5%; specificity, 77.0%) and late-arriving patients (sensitivity, 83.7%; specificity, 90.0%).
Conclusion:
CTP ASPECTS might be useful in predicting target mismatch derived from automated perfusion analysis software, and assisting in patient selection for endovascular therapy.
More Related Videos
09:59A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
Published on: September 16, 2017
06:45Author Spotlight: Integrated Photoacoustic, Ultrasound, and Angiographic Tomography (PAUSAT) for NonInvasive Whole-Brain Imaging of Ischemic Stroke
Published on: June 2, 2023