Related Experiment Video
Updated: Oct 8, 2025

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Reliability, Validity, and Responsiveness of the DEG, a Three-Item Dyspnea Measure
Duc M Ha1,2,3, Lubin R Deng4, Allison V Lange5
1Medical Service, Rocky Mountain Regional Veterans Affairs Medical Center, 1700 N Wheeling Street, Aurora, CO, 80045, USA. duc.ha@va.gov.
Background:
Dyspnea is a common and debilitating symptom that affects many different patient populations. Dyspnea measures should assess multiple domains.
Objective:
To evaluate the reliability, validity, and responsiveness of an ultra-brief, multi-dimensional dyspnea measure.
Design:
We adapted the DEG from the PEG, a valid 3-item pain measure, to assess average dyspnea intensity (D), interference with enjoyment of life (E), and dyspnea burden with general activity (G).
Participants:
We used data from a multi-site randomized clinical trial among outpatients with heart failure.
Main Measures:
We evaluated reliability (Cronbach's alpha), concurrent validity with the Memorial-Symptom-Assessment-Scale (MSAS) shortness-of-breath distress-orbothersome item and 7-item Generalized-Anxiety-Disorder (GAD-7) scale, knowngroups validity with New-York-Heart-Association-Functional-Classification (NYHA) 1-2 or 3-4 and presence or absence of comorbid chronic obstructive pulmonary disease (COPD), responsiveness with the MSAS item as an anchor, and calculated a minimal clinically important difference (MCID) using distribution methods.
Key Results:
Among 312 participants, the DEG was reliable (Cronbach's alpha 0.92). The mean (standard deviation) DEG score was 5.26 (2.36) (range 0-10) points. DEG scores correlated strongly with the MSAS shortness of breath distress-or-bothersome item (r=0.66) and moderately with GAD-7 categories (ρ=0.36). DEG scores were statistically significantly lower among patients with NYHA 1-2 compared to 3-4 [mean difference (standard error): 1.22 (0.27) points, p<0.01], and those without compared to with comorbid COPD [0.87 (0.27) points, p<0.01]. The DEG was highly sensitive to change, with MCID of 0.59-1.34 points, or 11-25% change.
Conclusions:
The novel, ultra-brief DEG measure is reliable, valid, and highly responsive. Future studies should evaluate the DEG's sensitivity to interventions, use anchor-based methods to triangulate MCID estimates, and determine its prognostic usefulness among patients with chronic cardiopulmonary and other diseases.
Related Concept Videos
Reliability and Validity
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...