Related Experiment Video
Updated: Oct 7, 2025

Software-Assisted Quantitative Measurement of Osteoarthritic Subchondral Bone Thickness
Published on: March 18, 2022
Intra- and inter-observer reliability of the novel vertebral bone quality score
Alex Mierke1, Omar Ramos2, Rhett Macneille2
1Department of Orthopaedic Surgery, Loma Linda University Health, Loma Linda Drive, Suite 213, 11406, Loma Linda, CA, United States of America. amierke@llu.edu.
Purpose:
To assess the intra- and inter-observer reliability of the novel vertebral bone quality (VBQ) scoring system.
Methods:
Four orthopedic surgery residents at various levels of training (PGY1-4) evaluated 100 noncontrast, T1-weighted MRIs of the lumbar spine. VBQ was calculated as quotient of the median of L1-L4 average signal intensity (SI) and the L3 cerebral spinal fluid (CSF) SI, as described by Ehresman et al. All measurements were repeated 2 weeks later. We performed a stratified analysis based on patient history of instrumentation, pathology, and MRI manufacturer/magnet strength to determine their effect on VBQ reliability. Spinal pathologies included compression fracture, burst fracture, vertebral osteomyelitis, epidural abscess, or neoplasm. The interclass correlation coefficient (ICC) two-way mixed model on absolute agreement was used to analyze inter-rater and intra-rater reliability. ICC less than 0.40 was considered poor, 0.40-0.59 as fair, 0.60-0.74 as good, and greater than 0.75 as excellent.
Results:
Intra-observer reliability was excellent (≥ 0.75) for all four observers. When stratified by history of spinal instrumentation or spinal pathology, all raters showed excellent intra-observer reliability except one (0.71 and 0.69, respectively). When stratified by MRI manufacturer, intra-observer reliability was ≥ 0.75 for all raters. Inter-observer reliability was excellent (0.91) and remained excellent (≥ 0.75) when stratified by history of spinal instrumentation, spinal pathology, or MRI-manufacturer.
Conclusions:
VBQ scores from spine lumbar MRIs demonstrate excellent intra-observer and inter-observer reliability. These scores are reliably reproduced in patients regardless of previous instrumentation, spinal pathology, or MRI manufacturer/magnetic field strength.
Related Concept Videos
Classification of Bones
Long and Short Bones
The appendicular skeleton, particularly the upper and lower limbs, is primarily made of long and short bones. The...
Articulations of the Vertebral Column
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Gross Anatomy of Bone
The diaphysis is the tubular shaft that runs between the proximal and distal ends of the bone. The walls of the diaphysis are composed of dense and hard compact bone made of numerous osteons — the functional unit of the compact bone. The hollow region in the diaphysis is called the medullary cavity, which harbors the bone marrow. In infants and children, this marrow cavity is filled with red marrow, whereas in...
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Reliability and Validity

