Related Experiment Video
Updated: Oct 7, 2025

Leaf Area Index Estimation Using Three Distinct Methods in Pure Deciduous Stands
Published on: August 29, 2019
The optimal spacing interval between principal shelterbelts of the farm-shelter forest network
Qinming Sun1,2,3, Bo Zheng2, Tong Liu4
1Agricultural College, Shihezi University, Shihezi, 832003, China.
Abstract:
The farm-shelter forest network is a complex grid protection system, with a windbreak that is distinctly different from that of the single shelterbelt. We selected the farm-shelter forest network of a jujube field in the Tarim Basin of northwest China and used a combination of field measurements and wind tunnel tests to determine the optimal spacing interval between principal shelterbelts. The wind speed reductive curve of the farm-shelter forest network showed a gradual wind speed tendency to stability. Therefore, a model was established based on the energy transfer balance between the upper and the lower airflows for a steady wind speed. The prediction error of the model was found to be < 1%. The model results indicated that increasing the spacing interval between principal shelterbelts from 10 to 20 H, where H is the shelterbelt height, maintained more than 70% of the windbreak effect of the farm-shelter forest network. If the spacing interval between principal shelterbelts were to be increased from 10 to 20 H, the jujube planting area would be increased by 0.54%. Therefore, a thorough consideration of the windbreak effect of each shelterbelt, the synergistic effects of shelterbelts, the windbreak effects of tall crops, and the effects of temperature and humidity in farm-shelter forest networks indicates that increasing the spacing interval will not only maintain the windbreak effect, but it will also reduce the side effects of shelterbelts, increase the planting area, favor mechanized operation, and improve planting efficiency.
More Related Videos
Related Concept Videos
Habitat Fragmentation
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Survival Tree
Building a Survival Tree
Constructing a...
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Design Example: Analyzing Capacity Contours for Flood Risk Assessment

