Predictors of radiation dose for uterine artery embolisation are angiography system-dependent
Don J Nocum1,2, John Robinson2,3, Mark Halaki4
1SAN Radiology & Nuclear Medicine, Sydney Adventist Hospital, Wahroonga, New South Wales, Australia.
This study sought to achieve radiation dose reductions for patients receiving uterine artery embolisation (UAE) by evaluating radiation dose measurements for the preceding generation (Allura) and upgraded (Azurion) angiography system. Previous UAE regression models in the literature could not be applied to this centre's practice due to being based on different angiography systems and radiation dose predictor variables. The aims of this study were to establish whether radiation dose is reduced with the upgraded angiography system and to develop a regression model to determine predictors of radiation dose specific to the upgraded angiography system. A comparison between Group I (Allura,n= 95) and Group II (Azurion,n= 95) demonstrated a significant reduction in kerma-area product (KAP) and Ka, r (reference air kerma) by 63% (143.2 Gy cm2vs 52.9 Gy cm2;P< 0.001,d= 0.8) and 67% (0.6 Gy vs 0.2 Gy;P< 0.001,d= 0.8), respectively. The multivariable linear regression (MLR) model identified the UAE radiation dose predictors for KAP on the upgraded angiography system as total fluoroscopy dose, Ka, r, and total uterus volume. The predictive accuracy of the MLR model was assessed using a Bland-Altman plot. The mean difference was 0.39 Gy cm2and the limits of agreement were +28.49 and -27.71 Gy cm2, and thus illustrated no proportional bias. The resultant MLR model was considered system-dependent and validated the upgraded angiography system and its advance capabilities to significantly reduce radiation dose. Interventional radiologist and interventional radiographer familiarisation of the system's features and the implementation of the newly established MLR model would further facilitate dose optimisation for all centres performing UAE procedures using the upgraded angiography system.
This study sought to achieve radiation dose reductions for patients receiving uterine artery embolisation (UAE) by evaluating radiation dose measurements for the preceding generation (Allura) and upgraded (Azurion) angiography system. Previous UAE regression models in the literature could not be applied to this centre's practice due to being based on different angiography systems and radiation dose predictor variables. The aims of this study were to establish whether radiation dose is reduced with the upgraded angiography system and to develop a regression model to determine predictors of radiation dose specific to the upgraded angiography system. A comparison between Group I (Allura,n= 95) and Group II (Azurion,n= 95) demonstrated a significant reduction in kerma-area product (KAP) and Ka, r (reference air kerma) by 63% (143.2 Gy cm2vs 52.9 Gy cm2;P< 0.001,d= 0.8) and 67% (0.6 Gy vs 0.2 Gy;P< 0.001,d= 0.8), respectively. The multivariable linear regression (MLR) model identified the UAE radiation dose predictors for KAP on the upgraded angiography system as total fluoroscopy dose, Ka, r, and total uterus volume. The predictive accuracy of the MLR model was assessed using a Bland-Altman plot. The mean difference was 0.39 Gy cm2and the limits of agreement were +28.49 and -27.71 Gy cm2, and thus illustrated no proportional bias. The resultant MLR model was considered system-dependent and validated the upgraded angiography system and its advance capabilities to significantly reduce radiation dose. Interventional radiologist and interventional radiographer familiarisation of the system's features and the implementation of the newly established MLR model would further facilitate dose optimisation for all centres performing UAE procedures using the upgraded angiography system.
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...