Related Experiment Video
Updated: Oct 7, 2025

A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
Single enrichment systems possibly underestimate both exposures and biological effects of organic pollutants from
Lan Yang1, Ying Zhou2, Li Chen1
1Center for Water and Health, Key Lab of Health Technology Assessment, National Health Commission, Key Laboratory of Public Health and Safety, Ministry of Education, Department of Environmental Health, School of Public Health, Fudan University, P.O. Box 249, Yi Xue Yuan Road 138, Shanghai, 200032, China.
Abstract:
Comprehensive enrichment of contaminants in drinking water is an essential step for accurately determining exposure levels of contaminants and testing their biological effects. Traditional methods using a single absorbent for enriching contaminants in water might not be adequate for complicated matrices with different physical-chemical profiles. To examine this hypothesis, we used an integrated enrichment system that had three sequential stages-XAD-2 resin, poly (styrene-divinylbenzene) and activated charcoal to capture organic pollutants and disinfection by-products (DBPs) from drinking water in Shanghai. Un-adsorbed Organic Compounds in Eluates (UOCEs) named UOCEs-A, -B, and-C following each adsorption stage were determined by gas chromatography-mass spectrometry to evaluate adsorption efficiency of the enrichment system. Meanwhile, biological effects such as cytotoxicity, effects on reactive oxygen species (ROS) generation and glutathione (GSH) depletion were determined in human LO2 cells to identify potential adverse effects on exposure to low dose contaminants. We found that poly-styrene-divinylbenzene (PS-DVB) and activated charcoal (AC) could still partly collect UOCEs-A and-B that the upper adsorption column incompletely captured, and that potential carcinogens like 2-naphthamine were present in all eluates. UOCEs-A at (1-4000), UOCEs-B at (1000-4000), and UOCEs-C at (2400-4000) folds of the actual concentrations had significant cytotoxicity to LO2 cells. Additionally, ROS and GSH change in cells treated with UOCEs indicated the potential for long-term effects of exposure to some mixtures of contaminants such as DBPs at low doses. These results suggested that an enriching system with a single adsorbent would underestimate the exposure level of pollutants and the biological effects of organic pollutants from drinking water. Effective methods for pollutants' enrichment and capture of drinking water should be given priority in future studies on accurate evaluation of biological effects exposed to mixed pollutants via drinking water.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016