Related Experiment Video
Updated: Oct 7, 2025

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Quantitative analysis of late iodine enhancement using dual-layer spectral detector computed tomography: comparison
Peijun Liu1, Lu Lin1, Cheng Xu1
1Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background:
To evaluate the segmental myocardial extracellular volume (ECV) fraction and to define a threshold ECV value that can be used to distinguish positive late gadolinium enhancement (LGE) segments from negative myocardial segments using dual-layer spectral detector computed tomography (SDCT), with magnetic resonance imaging (MRI) as a reference.
Methods:
Fifty-six subjects with cardiac disease or suspected cardiac disease, underwent both late iodine enhancement on CT (CT-LIE) scanning and late gadolinium enhancement on MRI (MRI-LGE) scanning. Each procedure occurred within a week of the other. Global and segmental ECVs of the left ventricle were measured by CT and MRI images. According to the location and pattern of delayed enhancement on MRI image, myocardial segments were classified into 3 groups: ischemic LGE segments (group 1), nonischemic LGE segments (group 2) and negative LGE segments (group 3). The correlation and agreement between CT-ECV and MRI-ECV were compared on a per-segment basis. Receiver operating characteristic (ROC) curve analysis was performed to establish a threshold for LIE detection.
Results:
Among the 56 patients, 896 segments were analyzed, and of these, 73 segments were in group 1, 229 segments were in group 2, and 594 segments were in group 3. In segmental analysis, CT-ECV in group 3 (27.0%; 24.9-28.9%) was significantly lower than that in group 1 (33.2%; 30.7-36.3%) and group 2 (34.9%; 32.3-39.8%; all P<0.001). Good correlations were seen between CT-ECV and MRI-ECV for all groups (group 1: r=0.920; group 2: r=0.936; group 3: r=0.799; all P<0.001). Bland-Altman analysis between CT-ECV and MRI-ECV showed a small bias in all 3 groups (group 1: -2.1%, 95% limits of agreement -11.3-7.1%; group 2: -0.6%, 95% limits of agreement -13.1-11.9%; group 3: 1.0%, 95% limits of agreement -12.7-14.7%). CT-ECV could differentiate between LGE-positive and LGE-negative segments with 83.1% sensitivity and 93.3% specificity at a cutoff of 31%.
Conclusions:
ECV values derived from CT imaging showed good correlation and agreement with MR imaging findings, and CT-ECV provided high diagnostic accuracy for discriminating between LGE-positive and LGE-negative segments. Thus, cardiac CT imaging might be a suitable noninvasive imaging technique for myocardial ECV quantification.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography

