Stability-indicating liquid chromatography method development and validation for impurity profiling of montelukast

Mohan Pasham1, Sharath Babu Haridasyam1, N V V D Praveen Boppy1

  • 1Department of Chemistry, GITAM, Hyderabad, Telangana, India.

Related Concept Videos

Clinically Relevant Drug Product Specifications: Methods of Establishment01:29

Clinically Relevant Drug Product Specifications: Methods of Establishment

Product specifications define the acceptable quality of a pharmaceutical product by ensuring identity, purity, potency, and strength. These specifications serve as benchmarks during development, manufacturing, and post-approval quality control. Clinically relevant specifications are particularly important because they directly relate to a drug's safety and efficacy in clinical use.Dissolution studies are critical biopharmaceutic tools that link in vitro behavior to in vivo performance. They...
10
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
778
Data Validation01:15

Data Validation

Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
289
Drug Dissolution: Requirements and Profile Comparison01:14

Drug Dissolution: Requirements and Profile Comparison

The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
30
Drug Product Stability01:16

Drug Product Stability

The long-term stability of drug products is critical to ensuring their quality, safety, and effectiveness over time. Stability directly influences a product's ability to maintain its intended characteristics, ensuring it performs as expected during its intended shelf life. Key attributes such as drug potency, impurities, dissolution, and other physicochemical measures of performance are tested to assess stability. These parameters indicate how well the product retains its quality over time and...
15
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
2.2K