Introduction:
Amputation outcome after heat press injury is associated with insufficient perfusion. We aimed to determine other risk factors for heat press injury and mechanisms of insufficient perfusion associated with amputation.
Methods:
We retrospectively classified 120 inpatients into the emergency and clinic groups, with arrival time before and after 48 h of injury, respectively. We performed propensity score-match to identify significant variables and combine them with those previously identified. Patients with or without amputation were categorized in different subgroups according to arrival time and perfusion with receiver-operator-characteristic (ROC) curves.
Results:
In the emergently insufficient perfusion subgroup, red blood cell distribution width of standard deviation (RDW-SD) was statistically different between patients without and with amputation (cutoff = 43 fL; specificity = 0.909). In the urgent group, neutrophil-lymphocyte-ratio (NLR) and relative lymphocyte count (L%) showed no association with perfusion, but was associated with amputation (NLR cutoff value = 3.12; sensitivity = 0.846). Differential leukocytes and related ratios (both groups), D-dimer (emergency group), and creatine kinase (CK) (clinic group) were also associated with insufficient perfusion.
Conclusion:
The study showed some correlations. Inflammation variables, D-dimer, and CK were associated with amputation and perfusion after heat press injury. Several factors were associated with amputation, including RDW-SD increase in insufficiently perfused patients within 48 h of injury, and NLR increase and L% decrease in patients after 48 h post-injury.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease IV: Nursing Management
Peripheral Artery Disease V: Postoperative Nursing Management
Burn Injuries
The damage results in the death of skin cells, which can lead to a massive loss of fluid. Dehydration, electrolyte imbalance, and renal and circulatory failure follow, which can be fatal. Burn patients are treated with intravenous fluids to offset...