Related Experiment Video
Updated: Oct 7, 2025

Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Effects of plate contouring quality on the biomechanical performance of high tibial osteotomy fixation: A parametric
Zahra Hayatbakhsh1, Farzam Farahmand2
1Department of Biomedical Engineering, Science and Research branch, Islamic Azad University, Tehran, Iran.
Abstract:
Locking plates have threaded holes, in which threaded-head screws are affixed. Hence, they do not need to be in intimate contact with underlying bone to provide fixation. There are, however, reports that a large distance between the plate and the bone might cause clinical complications such as delayed union or nonunion, screw pull out, and screw and plate breakage. Considering the diversity in the capabilities and costs of different plate customization techniques, the purpose of this study was to investigate the effect of the plate contouring quality on the biomechanical performance of high tibial osteotomy (HTO) fixation. A finite element model of proximal tibia was developed in Abaqus, using the QCT data of a cadaver. The model was then subjected to open-wedge HTO (correction angle 12°) with TomoFix plate fixation. The sagittal curvature of the plate was changed parametrically to provide certain levels of geometrical fit, and the biomechanical performance parameters of fixation were assessed. Results indicated 5%, 9% and 38% increase in the stiffness of the construct, and the von Mises stress in the plate and locking screw just above the osteotomy site, respectively, when the level of fit of plate changed from 0% (initial non-contoured initial shape) to 100% (fully adapted shape). The same change decreased the pressure at the lateral hinge of the osteotomy by 61%, and the mean of the tensile stress on the screw shaft by 12%. It was concluded that the level of fit has conflicting effects on the biomechanical parameters of the HTO fixation system, that is, the structural stiffness, the pressure at the lateral hinge, the stresses in the plate and screws, and the pull out resistance of the screws. In particular, for HTO patients with high quality bone, the optimal level of fit should provide a tradeoff between these parameters.
More Related Videos
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
08:15Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023