Related Experiment Video
Updated: Oct 7, 2025

Simultaneous Brightfield, Fluorescence, and Optical Coherence Tomographic Imaging of Contracting Cardiac Trabeculae Ex Vivo
Published on: October 2, 2021
Investigation of multiple scattering in space and spatial-frequency domains: with application to the analysis of
Meiqi Wu1, Siyang Liu2, Nichaluk Leartprapun1
1Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY 14853, USA.
Abstract:
Optical microscopy suffers from multiple scattering (MS), which limits the optical imaging depth into scattering media. We previously demonstrated aberration-diverse optical coherence tomography (AD-OCT) for MS suppression, based on the principle that for datasets acquired with different aberration states of the imaging beam, MS backgrounds become decorrelated while single scattering (SS) signals remain correlated, so that a simple coherent average can be used to enhance the SS signal over the MS background. Here, we propose a space/spatial-frequency domain analysis framework for the investigation of MS in OCT, and apply the framework to compare AD-OCT (using astigmatic beams) to standard Gaussian-beam OCT via experiments in scattering tissue phantoms. Utilizing this framework, we found that increasing the astigmatic magnitude produced a large drop in both MS background and SS signal, but the decay experienced by the MS background was larger than the SS signal. Accounting for the decay in both SS signal and MS background, the overall signal-to-background ratio (SBR) of AD-OCT was similar to the Gaussian control after about 10 coherent averages, when deeper line foci was positioned at the plane-of-interest and the line foci spacing was smaller than or equal to 80 µm. For an even larger line foci spacing of 160 µm, AD-OCT resulted in a lower SBR than the Gaussian-beam control. This work provides an analysis framework to gain deeper levels of understanding and insights for the future study of MS and MS suppression in both the space and spatial-frequency domains.
More Related Videos
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Interference and Diffraction
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

