Related Experiment Video
Updated: Oct 7, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Fundamental Investigations of Bond Behaviour of High-Strength Micro Steel Fibres in Ultra-High Performance Concrete
Jan-Paul Lanwer1, Svenja Höper2, Lena Gietz2
1iBMB (Institute of Building Materials, Concrete Construction and Fire Safety), Division of Concrete Construction, Faculty of Architecture, Civil Engineering and Environmental Science, Technische Universität Braunschweig, 38106 Braunschweig, Germany.
Abstract:
The objective of the contribution is to understand the fatigue bond behaviour of brass-coated high-strength micro steel fibres embedded in ultra-high performance concrete (UHPC). The study contains experimental pullout tests with variating parameters like load amplitude, fibre orientation, and fibre-embedded length. The test results show that fibres are generally pulled out of the concrete under monotonic loading and rupture partly under cyclic tensile loading. The maximum tensile stress per fibre is approximately 1176 N/mm2, which is approximately one third of the fibre tensile strength (3576 N/mm2). The load-displacement curves under monotonic loading were transformed into a bond stress-slip relationship, which includes the effect of fibre orientation. The highest bond stress occurs for an orientation of 30° by approximately 10 N/mm2. Under cyclic loading, no rupture occurs for fibres with an orientation of 90° within 100,000 load changes. Established S/N-curves of 30°- and 45°-inclined fibres do not show fatigue resistance of more than 1,000,000 load cycles for each tested load amplitude. For the simulation of fibre pullout tests with three-dimensional FEM, a model was developed that describes the local debonding between micro steel fibre and the UHPC-matrix and captures the elastic and inelastic stress-deformation behaviour of the interface using plasticity theory and a damage formulation. The model for the bond zone includes transverse pressure-independent composite mechanisms, such as adhesion and micro-interlocking and transverse pressure-induced static and sliding friction. This allows one to represent the interaction of the coupled structures with the bond zone. The progressive cracking in the contact zone and associated effects on the fibre load-bearing capacity are the decisive factors concerning the failure of the bond zone. With the developed model, it is possible to make detailed statements regarding the stress-deformation state along the fibre length. The fatigue process of the fibre-matrix bond with respect to cyclic loading is presented and analysed in the paper.
Related Concept Videos
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Fiber Reinforced Concrete
Microcracking in Concrete
Relation Between Tensile Strength and Compressive Strength of Concrete
Bonding and Strength of Aggregate
Reinforcements in Concrete