X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Two-Exposure Image Fusion Based on Optimized Adaptive Gamma Correction
Yan-Tsung Peng1, He-Hao Liao1, Ching-Fu Chen1
1Department of Computer Science, National Chengchi University, Taipei City 116, Taiwan.
Abstract:
In contrast to conventional digital images, high-dynamic-range (HDR) images have a broader range of intensity between the darkest and brightest regions to capture more details in a scene. Such images are produced by fusing images with different exposure values (EVs) for the same scene. Most existing multi-scale exposure fusion (MEF) algorithms assume that the input images are multi-exposed with small EV intervals. However, thanks to emerging spatially multiplexed exposure technology that can capture an image pair of short and long exposure simultaneously, it is essential to deal with two-exposure image fusion. To bring out more well-exposed contents, we generate a more helpful intermediate virtual image for fusion using the proposed Optimized Adaptive Gamma Correction (OAGC) to have better contrast, saturation, and well-exposedness. Fusing the input images with the enhanced virtual image works well even though both inputs are underexposed or overexposed, which other state-of-the-art fusion methods could not handle. The experimental results show that our method performs favorably against other state-of-the-art image fusion methods in generating high-quality fusion results.
Related Concept Videos
Deconvolution
Deconvolution involves several mathematical techniques to derive the impulse response. One common approach is polynomial division. In this method, the input and output sequences are treated as coefficients of...
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
Super-resolution Fluorescence Microscopy