Modeling and Calibration for Dithering of MDRLG and Time-Delay of Accelerometer in SINS
Jinlong Xing1, Gongliu Yang1,2, Tijing Cai1
1School of Instrument Science and Engineering, Southeast University, Nanjing 210018, China.
Abstract:
At present, the design and manufacturing technology of mechanically dithered ring laser gyroscope (MDRLG) have matured, the strapdown inertial navigation systems (SINS) with MDRLG have been widely used in military and business scope. When the MDRLG is working, high-frequency dithering is introduced, which will cause the size effect error of the accelerometer. The accelerometer signal has a time delay relative to the system, which will cause the accelerometer time delay error. In this article, in order to solve the above-mentioned problem: (1) we model the size effect error of the mechanically dithering of the MDRLG and perform an error analysis for the size effect error of the mechanically dithering of the MDRLG; (2) we model the time delay error of accelerometer and perform an error analysis for the time delay error of accelerometer; (3) we derive a continuous linear 43-D SINS error model considering the above-mentioned two error parameters and expand the temperature coefficients of accelerometers, inner lever arm error, outer lever arm error parameters to achieve high-precision calibration of SINS. We use the piecewise linear constant system (PWCS) method during the calibration process to prove that all calibration parameters are observable. Finally, the SINS with MDRLG is used in laboratory conditions to test the validity of the calibration method.
More Related Videos
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
11:57Three-dimensional Super Resolution Microscopy of F-actin Filaments by Interferometric PhotoActivated Localization Microscopy iPALM
Published on: December 1, 2016
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...