'Aggregation-Induced Emission' Active Mono-Cyclometalated Iridium(III) Complex Mediated Efficient Vapor-Phase

Pramod C Raichure1, Vishal Kachwal1,2, Inamur Rahaman Laskar1

  • 1Department of Chemistry, Birla Institute of Technology and Science, Pilani Campus, Pilani 333031, Rajasthan, India.

Related Concept Videos

Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
570
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
947
Carboxylic Acids to Methylesters: Alkylation using Diazomethane01:33

Carboxylic Acids to Methylesters: Alkylation using Diazomethane

Carboxylic acids react with diazomethane in an ether solvent via alkylation at the carboxylate oxygen atom to give methyl esters of the corresponding acid with excellent yields.
2.4K
Cycloaddition Reactions: MO Requirements for Photochemical Activation01:12

Cycloaddition Reactions: MO Requirements for Photochemical Activation

Some cycloaddition reactions are activated by heat, while others are initiated by light. For example, a [2 + 2] cycloaddition between two ethylene molecules occurs only in the presence of light. It is photochemically allowed but thermally forbidden.
2.2K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
717