Related Experiment Video
Updated: Oct 7, 2025

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Reliability of hip joint position sense tests using a clinically applicable measurement tool in elderly participants
Ravi Shankar Reddy1, Jaya Shanker Tedla2, Mastour Saeed Alshahrani2
1Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia. rshankar@kku.edu.sa.
Abstract:
Hip joint proprioception is vital in maintaining posture and stability in elderly individuals. Examining hip joint position sense (JPS) using reliable tools is important in contemporary clinical practice. The objective of this study is to evaluate the intra-rater and inter-rater reliability of hip JPS tests using a clinically applicable measurement tool in elderly individuals with unilateral hip osteoarthritis (OA). Sixty-two individuals (mean age = 67.5 years) diagnosed with unilateral hip OA participated in this study. The JPS tests were evaluated using a digital inclinometer in hip flexion and abduction directions. The absolute difference between target and reproduced angle (repositioning error) in degrees was taken to measure JPS accuracy. The intraclass correlation coefficient (ICC (2.k), was used to assess the reliability. The Intra rater-reliability for hip JPS tests showed very good agreement in the lying position (hip flexion-ICC = 0.88-0.92; standard error of measurement (SEM) = 0.06-0.07, hip abduction-ICC = 0.89-0.91; SEM = 0.06-0.07) and good agreement in the standing position (hip flexion-ICC = 0.69-0.72; SEM = 0.07, hip abduction-ICC = 0.66-0.69; SEM = 0.06-0.08). Likewise, inter-rater reliability for hip JPS tests demonstrated very good agreement in the lying position (hip flexion-ICC = 0.87-0.89; SEM = 0.06-0.07, hip abduction-ICC = 0.87-0.91; SEM = 0.07) and good agreement in the standing position (hip flexion-ICC = 0.64-0.66; SEM = 0.08, hip abduction-ICC = 0.60-0.72; SEM = 0.06-0.09). The results support the use of hip JPS tests in clinical practice and should be incorporated in assessing and managing elderly participants with hip OA.
More Related Videos
07:22Glycemic Impact on Knee Osteoarthritis Symptoms on Physical, Radiographic, and Inflammatory Markers among Individuals Aged 50 and Over with Diabetes
Published on: March 7, 2025
06:52An Inertial Measurement Unit Based Method to Estimate Hip and Knee Joint Kinematics in Team Sport Athletes on the Field
Published on: May 26, 2020