Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

3.0K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
3.0K
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving01:29

Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving

115
Mechanistic models play a crucial role in algorithms for numerical problem-solving, particularly in nonlinear mixed effects modeling (NMEM). These models aim to minimize specific objective functions by evaluating various parameter estimates, leading to the development of systematic algorithms. In some cases, linearization techniques approximate the model using linear equations.
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
115
Distributions to Estimate Population Parameter01:26

Distributions to Estimate Population Parameter

4.3K
The accurate values of population parameters such as population proportion, population mean, and population standard deviation (or variance) are usually unknown. These are fixed values that can only be estimated from the data collected from the samples. The estimates of each of these parameters are sample proportion, the sample mean, and sample standard deviation (or variance). To obtain the values of these sample statistics, data are required that have particular distribution and central...
4.3K
Mechanistic Models: Compartment Models in Individual and Population Analysis01:23

Mechanistic Models: Compartment Models in Individual and Population Analysis

100
Mechanistic models are utilized in individual analysis using single-source data, but imperfections arise due to data collection errors, preventing perfect prediction of observed data. The mathematical equation involves known values (Xi), observed concentrations (Ci), measurement errors (εi), model parameters (ϕj), and the related function (ƒi) for i number of values. Different least-squares metrics quantify differences between predicted and observed values. The ordinary least...
100
Instrument Calibration01:12

Instrument Calibration

323
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
323
Propagation of Uncertainty from Systematic Error01:10

Propagation of Uncertainty from Systematic Error

974
The atomic mass of an element varies due to the relative ratio of its isotopes. A sample's relative proportion of oxygen isotopes influences its average atomic mass. For instance, if we were to measure the atomic mass of oxygen from a sample, the mass would be a weighted average of the isotopic masses of oxygen in that sample. Since a single sample is not likely to perfectly reflect the true atomic mass of oxygen for all the molecules of oxygen on Earth, the mass we obtain from this...
974

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Modeling Highlights the Challenge of Achieving and Maintaining Hepatitis C Virus Micro-Elimination Among People Who Inject Drugs.

Open forum infectious diseases·2026
Same author

Modeling in vitro cell-to-cell spread of hepatitis C viral infection using an agent-based approach.

bioRxiv : the preprint server for biology·2026
Same author

Uncertainty Aware Decision Support with Computationally Expensive Simulation Models: A Case Study of HIV Intervention Scenarios.

medRxiv : the preprint server for health sciences·2026
Same author

Temporal and geographic analyses of colorectal cancer screening during and after the COVID-19 pandemic in a federally qualified health center.

PloS one·2026
Same author

Projected Demographic Trends in the Likelihood of Having or Becoming a Dementia Family Caregiver in the U.S. Through 2060.

Populations·2026
Same author

CRC-SPIN version 3.0: an updated policy model for colorectal cancer screening that includes the serrated pathway.

Journal of the National Cancer Institute·2026

Related Experiment Video

Updated: Oct 6, 2025

High-Throughput Metabolic Profiling for Model Refinements of Microalgae
11:07

High-Throughput Metabolic Profiling for Model Refinements of Microalgae

Published on: December 4, 2021

3.9K

Sequentially calibrating a Bayesian microsimulation model to incorporate new information and assumptions.

Maria DeYoreo1, Carolyn M Rutter2, Jonathan Ozik3

  • 1RAND Corporation, 1776 Main St., Santa Monica, CA, 90401, USA. mdeyoreo@rand.org.

BMC Medical Informatics and Decision Making
|January 13, 2022
PubMed
Summary

This study introduces a faster method for calibrating microsimulation models using a sequential Bayesian approach. This technique improves the accuracy of cancer progression models by efficiently incorporating new data, enhancing policy decision-making.

More Related Videos

Development of an Individual-Tree Basal Area Increment Model using a Linear Mixed-Effects Approach
04:35

Development of an Individual-Tree Basal Area Increment Model using a Linear Mixed-Effects Approach

Published on: July 3, 2020

3.4K
A Novel Bayesian Change-point Algorithm for Genome-wide Analysis of Diverse ChIPseq Data Types
12:39

A Novel Bayesian Change-point Algorithm for Genome-wide Analysis of Diverse ChIPseq Data Types

Published on: December 10, 2012

11.4K

Related Experiment Videos

Last Updated: Oct 6, 2025

High-Throughput Metabolic Profiling for Model Refinements of Microalgae
11:07

High-Throughput Metabolic Profiling for Model Refinements of Microalgae

Published on: December 4, 2021

3.9K
Development of an Individual-Tree Basal Area Increment Model using a Linear Mixed-Effects Approach
04:35

Development of an Individual-Tree Basal Area Increment Model using a Linear Mixed-Effects Approach

Published on: July 3, 2020

3.4K
A Novel Bayesian Change-point Algorithm for Genome-wide Analysis of Diverse ChIPseq Data Types
12:39

A Novel Bayesian Change-point Algorithm for Genome-wide Analysis of Diverse ChIPseq Data Types

Published on: December 10, 2012

11.4K

Area of Science:

  • Epidemiology
  • Mathematical Modeling
  • Biostatistics

Background:

  • Microsimulation models simulate individual event histories for population-level analysis and policy decisions.
  • Model calibration is crucial for predictions but can be computationally intensive.
  • Accurate calibration requires incorporating diverse evidence and quantifying uncertainty.

Purpose of the Study:

  • To develop a sequential updating technique to accelerate microsimulation model calibration.
  • To improve the calibration of a colorectal cancer natural history model using a Bayesian approach.
  • To enhance the estimation of cancer sojourn time and screening detection rates.

Main Methods:

  • Developed a sequential Bayesian calibration technique for efficient model updating.
  • Applied the method to re-calibrate a colorectal cancer microsimulation model.
  • Incorporated new targets for cancer sojourn time and screening detection.

Main Results:

  • The sequential calibration approach proved more efficient than recalibrating from scratch.
  • New screening detection data significantly altered sojourn time estimates.
  • Increased mean sojourn time for colon and rectal cancers, improving model validity.

Conclusions:

  • Sequential recalibration efficiently updates microsimulation models with new data.
  • This method is valuable when original calibration targets need supplementation.