Related Experiment Video
Updated: Oct 6, 2025

Cell-free Biochemical Fluorometric Enzymatic Assay for High-throughput Measurement of Lipid Peroxidation in High Density Lipoprotein
Published on: October 12, 2017
Assessing the Accuracy of Estimated Lipoprotein(a) Cholesterol and Lipoprotein(a)-Free Low-Density Lipoprotein
Weili Zheng1,2, Michael Chilazi2, Jihwan Park3
1Department of Cardiology Heart Vascular and Thoracic InstituteCleveland Clinic Cleveland OH.
Abstract:
Background Accurate measurement of the cholesterol within lipoprotein(a) (Lp[a]-C) and its contribution to low-density lipoprotein cholesterol (LDL-C) has important implications for risk assessment, diagnosis, and treatment of atherosclerotic cardiovascular disease, as well as in familial hypercholesterolemia. A method for estimating Lp(a)-C from particle number using fixed conversion factors has been proposed (Lp[a]-C from particle number divided by 2.4 for Lp(a) mass, multiplied by 30% for Lp[a]-C). The accuracy of this method, which theoretically can isolate "Lp(a)-free LDL-C," has not been validated. Methods and Results In 177 875 patients from the VLDbL (Very Large Database of Lipids), we compared estimated Lp(a)-C and Lp(a)-free LDL-C with measured values and quantified absolute and percent error. We compared findings with an analogous data set from the Mayo Clinic Laboratory. Error in estimated Lp(a)-C and Lp(a)-free LDL-C increased with higher Lp(a)-C values. Median error for estimated Lp(a)-C <10 mg/dL was -1.9 mg/dL (interquartile range, -4.0 to 0.2); this error increased linearly, overestimating by +30.8 mg/dL (interquartile range, 26.1-36.5) for estimated Lp(a)-C ≥50 mg/dL. This error relationship persisted after stratification by overall high-density lipoprotein cholesterol and high-density lipoprotein cholesterol subtypes. Similar findings were observed in the Mayo cohort. Absolute error for Lp(a)-free LDL-C was +2.4 (interquartile range, -0.6 to 5.3) for Lp(a)-C<10 mg/dL and -31.8 (interquartile range, -37.8 to -26.5) mg/dL for Lp(a)-C≥50 mg/dL. Conclusions Lp(a)-C estimations using fixed conversion factors overestimated Lp(a)-C and subsequently underestimated Lp(a)-free LDL-C, especially at clinically relevant Lp(a) values. Application of inaccurate Lp(a)-C estimations to correct LDL-C may lead to undertreatment of high-risk patients.
More Related Videos
06:47Isolation and Analysis of Plasma Lipoproteins by Ultracentrifugation
Published on: January 28, 2021
11:13Enrichment of Native Lipoprotein Particles with microRNA and Subsequent Determination of Their Absolute/Relative microRNA Content and Their Cellular Transfer Rate
Published on: May 9, 2019
Related Concept Videos
Blood Studies for Cardiovascular System III: Serum Lipid Profile
Serum lipids are fats and fatty substances in the blood and are crucial for various bodily functions, including energy storage, cellular structure, and hormone production. Serum lipids consist of cholesterol, triglycerides, and phospholipids.
Cholesterol is a soft, fat-like substance found in all body cells. It is crucial for producing hormones, vitamin D, and substances that aid...
Cholesterol: Significance and Regulation
Considering cholesterol and...