Cost effectiveness of a 1-hour high-sensitivity troponin-T protocol: An analysis of the RAPID-TnT trial
Ming-Yu Anthony Chuang1,2, Emmanuel S Gnanamanickam1,2, Jonathan Karnon1
1College of Medicine & Public Health, Flinders University of South Australia, Adelaide, Australia.
Background:
To understand the economic impact of an accelerated 0/1-hour high-sensitivity troponin-T (hs-cTnT) protocol.
Objective:
To conduct a patient-level economic analysis of the RAPID-TnT randomised trial in patients presenting with suspected acute coronary syndrome (ACS).
Methods:
An economic evaluation was conducted with 3265 patients randomised to either the 0/1-hour hs-cTnT protocol (n = 1634) or the conventional 0/3-hour standard-of-care protocol (n = 1631) with costs reported in Australian dollars. The primary clinical outcome was all-cause mortality or new/recurrent myocardial infarction.
Results:
Over 12-months, mean per patient costs were numerically higher in the 0/1-hour arm compared to the conventional 0/3-hour arm (by $472.49/patient, 95% confidence interval [95 %CI]: $-1,380.15 to $2,325.13, P = 0.617) with no statistically significant difference in primary outcome (0/1-hour: 62/1634 [3.8%], 0/3-hour: 82/1631 [5.0%], HR: 1.32 [95 %CI: 0.95-1.83], P = 0.100). The mean emergency department (ED) length of stay (LOS) was significantly lower in the 0/1-hour arm (by 0.62 h/patient, 95 %CI: 0.85 to 0.39, P < 0.001), but the subsequent 12-month unplanned inpatient costs was numerically higher (by $891.22/patient, 95 %CI: $-96.07 to 1,878.50, P = 0.077). Restricting the analysis to patients with hs-cTnT concentrations ≤ 29 ng/L, mean per patient cost remained numerically higher in the 0/1-hour arm (by $152.44/patient, 95 %CI:$-1,793.11 to $2,097.99, P = 0.988), whilst the reduction in ED LOS was more pronounced (by 0.70 h/patient, 95 %CI: 0.45-0.95, P < 0.001).
Conclusions:
There were no differences in resource utilization between the 0/1-hour hs-cTnT protocol versus the conventional 0/3-hour protocol for the assessment of suspected ACS, despite improved initial ED efficiency. Further refinements in strategies to improve clinical outcomes and subsequent management efficiency are needed.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome I: Introduction