Monitoring of HTLV-1-associated diseases by proviral load quantification using multiplex real-time PCR
Evandra Strazza Rodrigues1, Suellen Salustiano1,2, Elaine Vieira Santos1
1Center for Cell-Based Research, Regional Blood Center of Ribeirão Preto, School of Medicine of Ribeirão Preto, University of São Paulo (USP), São Paulo, Brazil.
Abstract:
Proviral load (PVL) is one of the determining factors for the pathogenesis and clinical progression of the human T-lymphotropic virus type I (HTLV-1) infection. In the present study, we optimized a sensitive multiplex real-time PCR for the simultaneous detection and quantification of HTLV-1 proviral load and beta-globin gene as endogenous control. The values obtained for HTLV-1 PVL were used to monitor the clinical evolution in HTLV-1-infected individuals. A vector containing cloned DNA targets of the real-time PCR for the beta-globin gene and the HTLV-1pol region was constructed. For the reaction validation, we compared the amplification efficiency of the constructed vector and MT-2 cell line containing HTLV-1. The analytical sensitivity of the reaction was evaluated by the application of a standard curve with a high order of magnitude. PVL assay was evaluated on DNA samples of HTLV-1 seropositive individuals. The construct showed adequate amplification for the beta-globin and HTLV-1 pol genes when evaluated as multiplex real-time PCR (slope = 3.23/3.26, Y-intercept = 40.18/40.73, correlation coefficient r2 = 0.99/0.99, and efficiency = 103.98/102.78, respectively). The quantification of PVL using the MT-2 cell line was equivalent to the data obtained using the plasmidial curve (2.5 copies per cell). In HTLV-1-associatedmyelopathy/tropical spastic paraparesis patients, PVL was significantly higher (21315 ± 2154 copies/105 PBMC) compared to asymptomatic individuals (1253 ± 691 copies/105 PBMC). The obtained results indicate that the optimized HTLV-1 PVL assay using plasmidial curve can be applied for monitoring and follow-up of the progression of HTLV-1 disease. The use of a unique reference plasmid for both HTLV-1 and endogenous gene allows a robust and effective quantification of HTLV-1 PVL. In addition, the developed multiplex real-time PCR assay was efficient to be used as a tool to monitor HTLV-1-infected individuals.
More Related Videos
04:11Author Spotlight: Advancements and Challenges in Hepatitis B Virus Detection
Published on: December 15, 2023
07:24Single-Cell Multiplexed Fluorescence Imaging to Visualize Viral Nucleic Acids and Proteins and Monitor HIV, HTLV, HBV, HCV, Zika Virus, and Influenza Infection
Published on: October 29, 2020