Related Experiment Video
Updated: Oct 6, 2025

Creation of a High-Fidelity, Low-Cost, Intraosseous Line Placement Task Trainer via 3D Printing
Published on: August 17, 2022
Arterial Line Placement Pitfalls Can Be Demonstrated and Visualized With an Inexpensive, Wearable Trainer
Olivia Paradis1, Lauren Bitterman1, Kimberly H Park1
1Laboratory for Innovations in Medical Education, Loma Linda University School of Medicine, Loma Linda, California.
Background:
Radial arterial line placement is commonly performed in various clinical settings, including the emergency department. However, learners are successful on the first attempt only half of the time. Simulation can provide learners with procedure practice opportunities outside of clinical practice to increase confidence and chances of success.
Objectives:
We set out to build an arterial line trainer that would be inexpensive and reusable, wearable, anatomically realistic, and echogenic to allow for ultrasound use. We also hoped to devise a clear option that would allow for demonstration of procedure pitfalls.
Discussion:
The arterial line trainer requires 4 hours of assembly time and costs $160. This includes enough material to make 48 tissue pads. The ballistics gel pad is echogenic; it can be customized with clear gel for direct anatomic visualization or dyed gel for more realism. The trainer also has a pulsatile artery for practice using anatomic landmarks. Visualization of the following important arterial line placement pitfalls is possible: suboptimal angle of approach, inadequate advancement of the catheter, and through-and-through vessel puncture.
Conclusions:
Our inexpensive trainer can help physicians and physicians in training conceptualize, practice, and troubleshoot the pitfalls of arterial line placement. Training programs looking to help learners understand the mechanics of arterial line placement may find it a useful tool.
Related Concept Videos
Arteries of Lower Limbs
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Arteries of the Upper Limbs
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: